Installation and User manual Sleeve cleaning station 10/2007 Edition 24 2.9 Operation Step 1 Load 2 : T urn off power button. : Open the upper co ver . 2 There ar e sleeves with different lengths of ditches for the longi…

Installation and User manual Sleeve cleaning station
10/2007 Edition
23
2.8 Installation
: Connect the power cable to the connector at the back of the unit and to the power outlet (see
photo below).
: Connect the air hose to the entrance of regulator and to the air supply (see photo below).
: Check the air regulator an adjust it to 5 bar (0.5 Mpa).
: Ensure a clean and dry supply of compressed air, use filter if necessary!
2
2
2
Power cable
Air hose
Power connector
Air regulator

Installation and User manual Sleeve cleaning station
10/2007 Edition
24
2.9 Operation
Step 1 Load 2
: Turn off power button.
: Open the upper cover.
2
There are sleeves with different lengths of ditches for the longitudinal vacuum hole, see step 2.2
2
: Select sleeves with long and short ditch.
: Place sleeves in the sleeve set plate.
: Make sure that the sleeves sit properly by rotating the sleeve gently.
: Close the upper cover after set sleeves.
: Turn on power button.
Wait until power lamp turns on.
2
Step 2 Select mode 2
There are sleeves with different lengths of ditches(4 mm) for the longitudinal vacuum hole. 2
2
2
Do not mix both types in one cleaning process.
There are different strokes for both types, the wrong stroke might damage the sleeve. 2
2
: Push Mode Selector button.
Indication light (Amber) is ON for “short stroke”,
Indication light is OFF for “long stroke”.
2
Step 3 Start / Stop 2
: Push Start button (green).
The cleaning process will start automatically.
The equipment stops automatically (15 cycles, about 3 minutes). with a buzzer signal.
The operator will be notified through buzzer signal and lashing of the stop button (red indica-
tor).
: If you want to stop the cleaning process manually, push the STOP button (red).
Sleeves until 02/1997 26,5 mm
current series 30,5 mm
Installation and User manual Sleeve cleaning station
10/2007 Edition
25
Step 4 Unload 2
: Open the upper cover and take out the sleeves.
: Clean the suction plate of the sleeves.
2.10 Notes
– The O ring of sleeve may not sit properly into the sleeve set plate.
If the sleeve is slightly tilted, the upper cover may not lock properly and activate the safety sen-
sor, then the equipment will not start.
– Please take care when tightening the four screw knobs of the upper cover. If the tightening tor-
que is too strong, the upper cover will bend and damage the upper cover magnet (could not
hold by magnet, safety sensor activates).
– The equipment stops immediately if the upper cover is accidentally opened during operation
(the safety sensor is activated).
– The equipment will stop when air supply is cut off during operation, a short buzzer signal is ac-
tivated. The unit is reseted.
2.11 Tips
Prior to use this cleaning station, it is advisable for first time user to use the traditional drill bits to
remove dirt of the sleeves that may have been accumulated over time due to improper cleaning.
This is especially true for old sleeves that are poorly maintained.
If you use the cleaning station regularly this is not necessary any more. 2