Installation and User manual Sleeve cleaning station
10/2007 Edition
24
2.9 Operation
Step 1 Load 2
: Turn off power button.
: Open the upper cover.
2
There are sleeves with different lengths of ditches for the longitudinal vacuum hole, see step 2.2
2
: Select sleeves with long and short ditch.
: Place sleeves in the sleeve set plate.
: Make sure that the sleeves sit properly by rotating the sleeve gently.
: Close the upper cover after set sleeves.
: Turn on power button.
Wait until power lamp turns on.
2
Step 2 Select mode 2
There are sleeves with different lengths of ditches(4 mm) for the longitudinal vacuum hole. 2
2
2
Do not mix both types in one cleaning process.
There are different strokes for both types, the wrong stroke might damage the sleeve. 2
2
: Push Mode Selector button.
Indication light (Amber) is ON for “short stroke”,
Indication light is OFF for “long stroke”.
2
Step 3 Start / Stop 2
: Push Start button (green).
The cleaning process will start automatically.
The equipment stops automatically (15 cycles, about 3 minutes). with a buzzer signal.
The operator will be notified through buzzer signal and lashing of the stop button (red indica-
tor).
: If you want to stop the cleaning process manually, push the STOP button (red).
Sleeves until 02/1997 26,5 mm
current series 30,5 mm
Installation and User manual Sleeve cleaning station
10/2007 Edition
25
Step 4 Unload 2
: Open the upper cover and take out the sleeves.
: Clean the suction plate of the sleeves.
2.10 Notes
– The O ring of sleeve may not sit properly into the sleeve set plate.
If the sleeve is slightly tilted, the upper cover may not lock properly and activate the safety sen-
sor, then the equipment will not start.
– Please take care when tightening the four screw knobs of the upper cover. If the tightening tor-
que is too strong, the upper cover will bend and damage the upper cover magnet (could not
hold by magnet, safety sensor activates).
– The equipment stops immediately if the upper cover is accidentally opened during operation
(the safety sensor is activated).
– The equipment will stop when air supply is cut off during operation, a short buzzer signal is ac-
tivated. The unit is reseted.
2.11 Tips
Prior to use this cleaning station, it is advisable for first time user to use the traditional drill bits to
remove dirt of the sleeves that may have been accumulated over time due to improper cleaning.
This is especially true for old sleeves that are poorly maintained.
If you use the cleaning station regularly this is not necessary any more. 2
2
2
2
Installation and User manual Sleeve cleaning station
10/2007 Edition
26
2.12 Maintenance
: Remove the upper cover by unscrewing the four rotating knobs and clean the dust accumula-
ted in the equipment.
: Clean the upper cover due to the accumulation of dust from the cleaning process.
: Check the air filter and clean it, if necessary.
: Take out the sleeve set plate by opening the 6 bolts.
The sleeve set plate needs regular cleaning due to the accumulation of dust from the cleaning
process.
2
Please be careful not to bend the air nozzles when you re-install the sleeve set plate into position.2
2
2
2.12.1 Cleaning of the nozzle jets
: Remove the upper cover and press STOP button more than 2 seconds.
Cleaning nozzle jets will be come up gently and stop at top end position.
2
Keep clear nozzle jet moving area. 2
2
2
: Clean the nozzle jets.
2
: Press POWER button.
Nozzle jets will move down gently.
2
2