00197288-02_AI_TBO_SX12_V2_DE_EN.pdf - 第52页
3 Installation 3.7 Software Settings 52 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V2 Thick Board Option Option Dicke Leiterplatte 02/2019 3.7 Software Settings 3.7.1 Heavy Boards Fig.18: Heavy board funct…

3 Installation
3.6 Final Work
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V2 Thick Board Option Option Dicke Leiterplatte
02/2019
51
3.6 Final Work
Fig.16: Checking the conveyor height
► Check the height of the conveyor:
Use a thickness gauge to measure the
distance from the upper edge of the
gantry to the clamping rails and adjust
the distance, if necessary.
Measure the left, right and center of the
clamping rails each.
In SX1/SX2 V2 machines with the
"Thick Board" option, this distance will
be 176+/‑0.2mm with the clamping
rails.
Enter the measurements in the meas-
urement log and place this in the
machine log book after you have com-
pleted the work (see 4.1 "Measurement
Log" [}53]).
Fig.17: Laser warning label
► Reinsert the four screws fastening the
conveyor and tighten these. After tight-
ening these screws, perform the meas-
urement check again as the height may
change slightly during tightening.
► Replace the laser warning signs(1) on
the clamping rails which were removed
with the old clamping rails (SC:1piece,
DC:2pieces).

3 Installation
3.7 Software Settings
52 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V2 Thick Board Option Option Dicke Leiterplatte
02/2019
3.7 Software Settings
3.7.1 Heavy Boards
Fig.18: Heavy board function in SiplacePro Desk
Boards which are over a certain weight must be defined as heavy boards.
●
In single conveyors, enable the heavy board function for any boards weighing more than 2kg
(up to max. of 5kg).
●
In dual conveyors, enable the heavy board function for any boards weighing more than 1kg
(up to max. of 2kg).
The weight of the board must be determined with fully configured components and entered at
Setup – Conveyor.
NOTICE
Heavy boards
The conveyor speed is reduced for heavy boards.
When using heavy boards, be aware that the wear to the conveyor belt can be higher (=
product life is reduced).

4 Appendix
4.1 Measurement Log
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V2 Thick Board Option Option Dicke Leiterplatte
02/2019
53
4 Appendix
4.1 Measurement Log
Measurement and height deviation for distance between gantry and PCB conveyor
(for SC and DC)
Date Name Machine no.
Measured from the upper edge of the loose bearing tracks for the gantry to the conveyor
sides
____________ ____________ Output side
Input side
____________ ____________
____________ ____________ ____________ ____________
Measurement gantry 1 Measurement gantry 1
____________ ____________ ____________ ____________
____________ ____________ ____________ ____________
Lane 2 Lane 1
____________ ____________ Output side
Input side
____________ ____________
____________ ____________ ____________ ____________
Measurement gantry 2 Measurement gantry 2
____________ ____________ ____________ ____________
____________ ____________ ____________ ____________
Lane 2 Lane 1
MAX value MIN value Deviation in mm