3 Installation
3.3 Final Work
60 Montageanleitung / Assembly Instructions SIPLACE TX-Serie Basic Pack Vacuum Tooling 07/2017
3.3.1.1 Factory Settings
Parameter VSi-V VSi-P10 VSi-VP8
Switching point 1
Switching point mode and logic Two-point mode, normally closed (H.
no)
Switching point SP1 750 mbar 5500 mbar -750 mbar
Reset point rP1 600 mbar 5000 mbar -600 mbar
Window hysteresis Hy1 / leakage limit per sec L-1 20 mbar 100 mbar 20 mbar
Switch-on delay dS1, switch-off delay dr1 0ms 0ms 0ms
Switching point 2
Switching point mode and logic Two-point mode, normally closed (H.
no)
Switching point SP2 550 mbar 5000 mbar 5500 mbar
Reset point rP2 500 mbar 4500 mbar 5000 mbar
Window hysteresis Hy2 / leakage limit per sec L-2 20 mbar 100 mbar 20 mbar
Switch-on delay dS2, switch-off delay dr2 0ms 0ms 0ms
Transistor function PNP PNP PNP
Display unit mbar mbar mbar
Eco mode Off Off Off
Display alignment Standard Standard Standard
IO link device locks, extended device locks 0 0 0
Menu PIN code, NFC PIN code 000 000 000

3 Installation
3.3 Final Work
Montageanleitung / Assembly Instructions SIPLACE TX-Serie Basic Pack Vacuum Tooling 07/2017 61
3.3.1.2 Setting Switching Point 2 as Normally Open
Fig.5: Setting switching point 2 as normally open
Proceed as follows to set switching point 2 as normally open:
► Press the SET button.
► Press the SET button until you see the AF (Additional Functions) menu item.
► Press the MODE button. Ou1 appears on the display.
► Press the SET button until Ou2 appears.
► Press the MODE button. H.no appears on the display.
► Press the SET button until H.nc is on the display.
► Quit the menu.

3 Installation
3.3 Final Work
62 Montageanleitung / Assembly Instructions SIPLACE TX-Serie Basic Pack Vacuum Tooling 07/2017
3.3.1.3 Setting Switching Point 1
Fig.6: Setting switching point 1
Proceed as follows to set switching point 1:
► Press the SET button.
► Press the SET button until you see the SP1 (Switching Point 1) menu item.
► Press the MODE button. A value appears on the display. The one point flashes.
► Press the SET button and set a value 0-9.
► Press the MODE button. The tens point flashes.
► Press the SET button and set a value 0-9.
► Press the MODE button. The hundreds point flashes.
► Press the SET button and set a value 0-9.
► The display shall now show 450.
► Wait 2 seconds. SP1 appears on the display again.
► Continue with SET button – please refer to 3.3.1.4 "Setting Hysteresis Switching Point
1" [}63].