3 Installation 3.3 Final Work Montageanleitung / Assembly Instructions SIPLACE TX-Serie Basic Pack Vacuum Tooling 07/2017 61 3.3.1.2 Setting Switching Point 2 as Normally Open Fig.5: Setting switching point 2 as normall…

100%1 / 70
3 Installation
3.3 Final Work
60 Montageanleitung / Assembly Instructions SIPLACE TX-Serie Basic Pack Vacuum Tooling 07/2017
3.3.1.1 Factory Settings
Parameter VSi-V VSi-P10 VSi-VP8
Switching point 1
Switching point mode and logic Two-point mode, normally closed (H.
no)
Switching point SP1 750 mbar 5500 mbar -750 mbar
Reset point rP1 600 mbar 5000 mbar -600 mbar
Window hysteresis Hy1 / leakage limit per sec L-1 20 mbar 100 mbar 20 mbar
Switch-on delay dS1, switch-off delay dr1 0ms 0ms 0ms
Switching point 2
Switching point mode and logic Two-point mode, normally closed (H.
no)
Switching point SP2 550 mbar 5000 mbar 5500 mbar
Reset point rP2 500 mbar 4500 mbar 5000 mbar
Window hysteresis Hy2 / leakage limit per sec L-2 20 mbar 100 mbar 20 mbar
Switch-on delay dS2, switch-off delay dr2 0ms 0ms 0ms
Transistor function PNP PNP PNP
Display unit mbar mbar mbar
Eco mode Off Off Off
Display alignment Standard Standard Standard
IO link device locks, extended device locks 0 0 0
Menu PIN code, NFC PIN code 000 000 000
3 Installation
3.3 Final Work
Montageanleitung / Assembly Instructions SIPLACE TX-Serie Basic Pack Vacuum Tooling 07/2017 61
3.3.1.2 Setting Switching Point 2 as Normally Open
Fig.5: Setting switching point 2 as normally open
Proceed as follows to set switching point 2 as normally open:
► Press the SET button.
► Press the SET button until you see the AF (Additional Functions) menu item.
► Press the MODE button. Ou1 appears on the display.
► Press the SET button until Ou2 appears.
► Press the MODE button. H.no appears on the display.
► Press the SET button until H.nc is on the display.
► Quit the menu.
3 Installation
3.3 Final Work
62 Montageanleitung / Assembly Instructions SIPLACE TX-Serie Basic Pack Vacuum Tooling 07/2017
3.3.1.3 Setting Switching Point 1
Fig.6: Setting switching point 1
Proceed as follows to set switching point 1:
► Press the SET button.
► Press the SET button until you see the SP1 (Switching Point 1) menu item.
► Press the MODE button. A value appears on the display. The one point flashes.
► Press the SET button and set a value 0-9.
► Press the MODE button. The tens point flashes.
► Press the SET button and set a value 0-9.
► Press the MODE button. The hundreds point flashes.
► Press the SET button and set a value 0-9.
► The display shall now show 450.
► Wait 2 seconds. SP1 appears on the display again.
► Continue with SET button – please refer to 3.3.1.4 "Setting Hysteresis Switching Point
1" [}63].