TM4807.Long Board Partition Mount.pdf - 第16页

Error Number T itle Causes and measures 1291 1 Halfway Continue Error <Cause> Cannot start halfway continue when bo ard exists in ex it position because 2D code has to be recognized at “f irst half mount”. <Meas…

100%1 / 21
code is not recognizable at “first half mount”, data check error occurs.
When starting halfway continue, return board to the main stopper position if board exists
at the exit stopper position because 2D code have to be recognized at “first half mount”.
When a board exist at the exit stopper position, d
istributed
code data are not displayed in
code scan teach window.
Example: Usable board data (Board 2D code and block 2D code are recognizable at “first
half mount”)
4.8 Error message
Error
Number
Title Causes and measures
12910
Halfway Continue
Error
<Cause>
Cannot start halfway continue when board exists in exit
position because "first half mount" parts have to be
mounted at "first half mount".
Mount No.: XXX
Parts No.: XXX
<Measures>
To start halfway continue, return board to main stopper
position or check “Mounted” flag of “first half mount”
parts.
Board
Recognizable area of
first
half mount
Block
Block code
Board code
Error
Number
Title Causes and measures
12911
Halfway Continue
Error
<Cause>
Cannot start halfway continue when board exists in exit
position because 2D code has to be recognized at “first
half mount”.
<Measures>
To start halfway continue, return board to main stopper
position.
12912
Halfway Continue
Error
<Cause>
Cannot start halfway continue when board exists in exit
position because bad mark has to be recognized at
“first half mount”.
<Measures>
To start halfway continue, return board to main stopper
position.
24590
Board Data Error
<Cause>
Board fiducial for “second half mount” is not set.
<Measures>
Set “second half mount” board fiducial to No.1 of
[Board] - [Fiducial].
24591
Board Data Error
<Cause>
Local fiducial No.1 cannot be set in mount data.
In the case of "long board partition mount", local fiducial
No.1 is used as board fiducial for "second half mount".
Mount No.: XXX
<Measures>
Set the value after No.2 to local fiducial.
24592
Board Data Error
<Cause>
X coordinate or R coordinate of block offset is not
“0.000”.
Block No.: XXX
<Measures>
Set “0.000” to X coordinate and R coordinate of block
offset.
Error
Number
Title Causes and measures
24596
Board Data Error
<Cause>
Mount position is out of the moving area.
This mount can be mounted at neither "first half mount"
nor "second half mount".
Mount No.: XXX
<Measures>
Correct mount coordinates.
24597
Board Data Error
<Cause>
Local fiducial mark of following mount data is not
recognizable.
Mount No.: XXX
- Local fiducial corresponding to mount data of "first half
mount" is not recognizable at "first half mount".
- Local fiducial corresponding to mount data of "second
half mount" is not recognizable at "second half mount".
<Measures>
Correct local fiducial mark coordinates.
(Local fiducial corresponding to mount data of "first half
mount" has to be recognizable at "first half mount", and
local fiducial corresponding to mount data of "second
half mount" has to be recognizable at "second half
mount")