Error Number T itle Causes and measures 24596 Board Data Error <Cause> Mount position is out of the moving area. This mount can be mounted at neither " first half mount" nor "second half mount".…

100%1 / 21
Error
Number
Title Causes and measures
12911
Halfway Continue
Error
<Cause>
Cannot start halfway continue when board exists in exit
position because 2D code has to be recognized at “first
half mount”.
<Measures>
To start halfway continue, return board to main stopper
position.
12912
Halfway Continue
Error
<Cause>
Cannot start halfway continue when board exists in exit
position because bad mark has to be recognized at
“first half mount”.
<Measures>
To start halfway continue, return board to main stopper
position.
24590
Board Data Error
<Cause>
Board fiducial for “second half mount” is not set.
<Measures>
Set “second half mount” board fiducial to No.1 of
[Board] - [Fiducial].
24591
Board Data Error
<Cause>
Local fiducial No.1 cannot be set in mount data.
In the case of "long board partition mount", local fiducial
No.1 is used as board fiducial for "second half mount".
Mount No.: XXX
<Measures>
Set the value after No.2 to local fiducial.
24592
Board Data Error
<Cause>
X coordinate or R coordinate of block offset is not
“0.000”.
Block No.: XXX
<Measures>
Set “0.000” to X coordinate and R coordinate of block
offset.
Error
Number
Title Causes and measures
24596
Board Data Error
<Cause>
Mount position is out of the moving area.
This mount can be mounted at neither "first half mount"
nor "second half mount".
Mount No.: XXX
<Measures>
Correct mount coordinates.
24597
Board Data Error
<Cause>
Local fiducial mark of following mount data is not
recognizable.
Mount No.: XXX
- Local fiducial corresponding to mount data of "first half
mount" is not recognizable at "first half mount".
- Local fiducial corresponding to mount data of "second
half mount" is not recognizable at "second half mount".
<Measures>
Correct local fiducial mark coordinates.
(Local fiducial corresponding to mount data of "first half
mount" has to be recognizable at "first half mount", and
local fiducial corresponding to mount data of "second
half mount" has to be recognizable at "second half
mount")
Error
Number
Title Causes and measures
24598
Board Data Error
<Cause>
Local bad mark of following mount data is not
recognizable.
Mount No.: XXX
- Local bad mark corresponding to mount data of "first
half mount" is not recognizable at "first half mount".
- Local bad mark corresponding to mount data of
"second half mount" is not recognizable at "second half
mount".
<Measures>
Correct local bad mark coordinates.
(Local bad mark corresponding to mount data of "first
half mount" has to be recognizable at "first half mount",
and local bad mark corresponding to mount data of
"second half mount" has to be recognizable at "first half
mount" or "second half mount")
24599
Optimization
Uncompleted
Warning
<Cause>
This board data is not optimized correctly for "long
board partition mount".
When auto-running is started, “first half mount” and
“second half mount” of unoptimized mount are uniformly
decided from mount coordinates.
Unoptimized first mount no.: XXX
<Measures>
For more efficient mount, optimize board data.
24600
Machine Data Error
<Cause>
When using “Long board partition mount”, following
settings are required.
- [Machine] - [Machine Information] - [Installation] - [Exit
Stopper] : “Exist
- [Machine] - [Mechanical] - [Position] - [Fiducial All
Recognition] : “Not Use”
<Measures>
Change settings.