TM4807.Long Board Partition Mount.pdf - 第19页
Error Number T itle Causes and measures 24601 Board Data Error <Cause> Local bad mark position is outside moving area. Local bad mark No.: XXX <Measures> Change local bad mark position to movable area. 5 I/O …

Error
Number
Title Causes and measures
24598
Board Data Error
<Cause>
Local bad mark of following mount data is not
recognizable.
Mount No.: XXX
- Local bad mark corresponding to mount data of "first
half mount" is not recognizable at "first half mount".
- Local bad mark corresponding to mount data of
"second half mount" is not recognizable at "second half
mount".
<Measures>
Correct local bad mark coordinates.
(Local bad mark corresponding to mount data of "first
half mount" has to be recognizable at "first half mount",
and local bad mark corresponding to mount data of
"second half mount" has to be recognizable at "first half
mount" or "second half mount")
24599
Optimization
Uncompleted
Warning
<Cause>
This board data is not optimized correctly for "long
board partition mount".
When auto-running is started, “first half mount” and
“second half mount” of unoptimized mount are uniformly
decided from mount coordinates.
Unoptimized first mount no.: XXX
<Measures>
For more efficient mount, optimize board data.
24600
Machine Data Error
<Cause>
When using “Long board partition mount”, following
settings are required.
- [Machine] - [Machine Information] - [Installation] - [Exit
Stopper] : “Exist”
- [Machine] - [Mechanical] - [Position] - [Fiducial All
Recognition] : “Not Use”
<Measures>
Change settings.

Error
Number
Title Causes and measures
24601
Board Data Error
<Cause>
Local bad mark position is outside moving area.
Local bad mark No.: XXX
<Measures>
Change local bad mark position to movable area.
5 I/O address
In [Unit] – [I/O] screen, “STAGE-2 MAIN STOPPER HIGH END” is correspond to the exit
stopper high end sensor.
I/O address Type Contents I/O state
1 DETECT
N01008F7 CONV STAGE-2 MAIN STOPPER HIGH END
0
NOT
DETECT
6 Appendix
6.1 Setting method
This function is enabled with the following setting.
Select [Machine] -
[Machine Information] -
[Installation Setting] and
set [Long Board Partition
Mount Conveyor] to
“Exist”.
Select [Machine] -
[Machine Data] -
[Mechanical] - [Position]
and set [Distance exit
stopper to main stopper]
and [Exit stopper arrival
add time].

* Check that [Machine] - [Installation Setting] - [Exit stopper] is “Exist”.
* Check that [Machine] - [Mechanical] - [Position] - [Fiducial All Recognition] is “Not Use”.
6.1.1 Distance exit stopper to main stopper [mm]
Input the distance from the exit stopper to the main stopper. (Input a positive number
regardless of conveyor direction)
The standard values are as follows. There is individual difference of several millimeters
every machine.
Conveyor direction
R->L
Conveyor direction
R->L
"LED package specs. standard conveyor
(without extension)"
About 257.5mm About 309.5mm
"LED package specs. standard conveyor (with
extension)"
About 562.0mm About 615.0mm
6.1.1.1 Measurement procedure of “Distance exit stopper to main stopper”
An example of the procedure to measure “Distance exit stopper to main stopper” is as
follows.
1. Prepare a long board (length 550mm or more).
2. Input the board size to [Board] - [Board] - [Board size X] and [Board size Y].
3. Tap [Unit] - [Conveyor] - [Width] button and change conveyor width.
4. Put the board to the main stopper position and fix it. (Tap [Unit] - [Convey] - [Push Up]
and [Board Clamp] button)
5. Decide a target mark on the board (About 550 - 700mm position from the board edge. It
has to be recognizable also at the exit stopper position). Open [Board] - [Fiducial] -
Distance exit stopper to main stopper
Conveyor direction
Main stopper
Exit
stopper