2500_Users_Manual-.pdf - 第180页

↑ ↓ 1656-2 INCREASE DECREASE 2177-1 NORMAL HIGHER VALUE Preventive Maintenance Adjusting Press Bearings Make sure the dot matrix printer's application plate is aligned correctly by holding a device in your fingers a…

100%1 / 448
ENTER LABEL CALIBRATION VALUE (X):
ENTER LABEL ADJUST VALUE (X):
1944-1
NORMAL
HIGHER VALUE
Preventive
Maintenance
Adjusting
Position
of
Print
on
Label
(Dot
Matrix
Printer)
The
left-to-right
position
of
characters
on
the
label
is
determined
by
label
calibration.
Figure
5-6
Adjusting
Label
Calibration
You
can
change
the
label
calibration
setting
during
a
Task
run
by
pressing
STOP
and
then
LOWER
CASE
+
C.
The
2500
displays:
The
X
represents
the
current
setting.
The
default
setting
places
the
first
column
of
print
within
0.040
inches
of
the
leading
edge
of
the
label.
Increasing
the
value
one
unit
moves
the
print
location
approximately
0.005
inches
to
the
right;
decreasing
the
value
moves
it
0.005
inches
to
the
left.
Enter
a
number
from
0
to
255,
and
press
ENTER.
If
you
change
label
calibration,
press
CAL
to
calibrate
the
label
(see
page
4-19).
Adjusting
Position
of
Label
on
Device
(Dot
Matrix
Printer)
The
position
of
the
label
on
the
device
is
determined
by
the
label
placement
value.
This
is
set
in
the
system
defaults
to
“Auto
center,”
which
instructs
the
2500
to
place
the
label
on
the
true
center
of
the
device.
You
can
change
label
placement
using
a
local
mode
command
described
in
Appendix
F.
You
can
use
the
Label
Adjust
parameter
to
flne-tune
label
placement
and
thereby
adjust
its
centering
while
a
Task
is
running.
Press
STOP
and
then
LOWER
CASE
+
A.
The
2500
displays:
Enter
a
number
from
0
to
255;
each
unit
moves
the
label
0.01
inch
closer
to
the
trailing
edge.
Press
ENTER
to
accept
the
selection.
Note:
This
works
only
w
加避
"Aut。
center”
is
selected
in
the
2500
Setup/Labeler
menu.
ProMaster
2500
User
Manual
5-25
1656-2
INCREASE DECREASE
2177-1
NORMAL
HIGHER VALUE
Preventive
Maintenance
Adjusting
Press
Bearings
Make
sure
the
dot
matrix
printer's
application
plate
is
aligned
correctly
by
holding
a
device
in
your
fingers
and
sliding
it
across
the
application
plate,
over
the
press
bearings,
and
onto
the
bearing
plate
(see
Figure
2-8).
The
device
should
move
smoothly
across
the
press
bearings.
If
device
travel
is
not
smooth,
use
a
7/64-inch
hex
wrench
to
loosen
(to
raise)
or
tighten
(to
lower)
the
screw
on
the
left
side
of
the
plate
(near
the
bearings)
until
a
smooth
transition
occurs
(see
Figure
2-8).
Adjusting
Print
Position
on
the
Label
(Thermal
Printer)
Two
parameters
control
the
position
of
text
and
graphics
on
the
label.
By
changing
the
value
of
each
parameter,
the
location
of
the
text
or
graphics
printed
on
the
label
can
be
adjusted.
The
print
shift
value
affects
the
vertical
position
of
the
printed
image,
moving
the
position
of
characters
or
graphics
from
the
top
to
bottom
of
the
label
(Y
axis).
See
Figure
5-7.
The
label
calibration
value
affects
the
horizontal
position
of
the
printed
image
on
the
label,
moving
the
position
of
the
text
or
graphics
from
left
to
right
(X
axis).
See
Figure
5-8.
Figure
5-7
Print
Shift
(affects
vertical
position)
Figure
5-8
Label
Calibration
(affects
horizontal
position)
Print
Shift
Change
this
value
using
the
STOP
command
described
in
the
following
procedure.
1.
Press
STOP
to
pause
the
2500
while
a
Task
is
running.
2.
Press
LOWER
CASE
+
P.
The
display
on
the
2500
prompts
you
to
enter
a
new
value.
3.
Press
or
to
enter
a
new
print
shift
value
between
0
and
16.
Entering
a
larger
numeric
value
moves
the
printed
character
higher
on
the
label.
4.
Press
START
to
continue
running
the
Task.
5-26
ProMaster
2500
User
Manual
PROGRAM/TEST LABEL
SLAVE MODE PART TYPE: DIP 24-.3
PART TOTAL: 251 PART LENGTH: 1.250
LABEL CAL: (XXX)
Preventive
Maintenance
Label
Calibration
Label
Advance
Adjusting
the
Thermal
Printer
Change
the
label
calibration
value
using
the
STOP
command
described
in
the
following
procedure.
1.
Press
STOP
to
pause
the
2500
while
a
Task
is
running.
2.
Press
LOWER
CASE
+
C.
The
2500
displays:
where
XXX
represents
a
numeric
value
for
the
current
setting.
3.
Press
or
to
change
the
label
calibration
value
(the
range
is
from
0
to
255).
Entering
a
larger
numeric
value
moves
the
printed
characters
closer
to
the
leading
edge
of
the
label.
4.
Press
START
to
continue
running
the
Task.
The
label
advance
value
defines
how
far
a
label
is
extended
above
the
application
plate
just
before
it
is
applied
to
a
device
(see
Figure
5-14).
The
value
can
be
changed
by
pressing
STOP
and
LOWER
CASE
+
W.
Increasing
the
numeric
value
advances
the
label
farther
above
the
application
plate.
When
the
thermal
printer
is
operating
correctly,
the
label
and
ribbon
material
advance
smoothly
and
without
any
binding
or
excess
slack.
If
any
of
the
clutches
that
are
attached
to
the
rollers
begin
to
bind,
they
can
cause
the
feeding
and
advancing
of
both
label
and
ribbon
material
to
go
out
of
adjustment.
To
adjust
the
thermal
printer,
follow
these
steps
(see
Figure
5-9):
1.
Starting
with
the
ribbon
(supply)
roll
hub,
check
that
it
has
only
slight
friction.
Remove
the
ribbon
hub
and
spring
washer.
2.
Hold
the
spring
washer
in
your
hand
and,
using
small
needlenose
pliers,
bend
the
three
fingers
so
they
produce
less
(or
more,
if
required)
friction
on
the
hub.
3.
Reinstall
the
spring
washer
and
hub
on
the
printer.
Check
that
there
is
now
only
slight
friction.
4.
Print
a
label
and
observe
the
amount
of
slack
in
the
ribbon
when
the
printer
head
pivots
up
to
print.
The
ribbon
should
droop
down
about
3/4”
when
the
print
head
pivots
up.
If
it
does
not,
loosen
the
lock
nut
on
the
damper
at
the
top
of
the
air
cylinder
using
small
needlenose
pliers,
and
adjust
it
counterclockwise
with
a
small
flat-
blade
screwdriver
until
the
head
pivots
up
fast
enough
to
create
the
droop.
Then
tighten
the
lock
nut
with
the
small
needlenose
pliers.
ProMaster
2500
User
Manual
5-27