4.3. Error message
The table below is error message for this function.
Error No Content and Cause Checkpoint
2298
FEEDER MACS ERROR
Feeder MACS action is failed.
* In auto running, this error message is
displayed only [Use] in [Feeder MACS]
- [Error Stop].
-Check whether around the pickup position
is dirty.
-Check whether the database number for
Feeder MACS is right.
[Machine] - [Setting] - [Machine Data] -
[Precision] - [Pickup MACS] - [Feeder
MACS] - [Mark DB Number 1-3]
2299
FEEDER MACS CORRECTION
VALUE ERROR
The correction value by Feeder MACS
exceeds the limit.
-Check whether around the pickup position
is dirty.
2771
PICKUP MACS FILE READ ERROR
It failed to read Pickup MACS setting
file.
-Restore the machine data.
-Re-install application software.
2772
PICKUP MACS FILE WRITE ERROR
It failed to write Pickup MACS setting
file.
-Release the read only of file.
-Restore the machine data.
7998
NOZZLE MACS ERROR
Nozzle MACS action is failed.
-Check whether the nozzle is dirty.
-Check whether the mark data number for
Nozzle MACS is right.
[Machine] - [Setting] - [Machine Data] -
[Precision] - [Pickup MACS] - [Nozzle
MACS] - [Database No.]
7999
NOZZLE MACS CORRECTION
VALUE ERROR
The correction value by Nozzle MACS
exceeds the limit.
-Exchange or clean the nozzles.
24559
FEEDER MACS MARK DATA
READING ERROR
It was failed in reading mark data for
Feeder MACS.
-Check mark data number in [Machine] -
[Setting] - [Machine Data] - [Precision] -
[Pickup MACS] - [Feeder MACS] - [Mark
DB Number].
-Check the accessible to the database.
24574
NOZZLE MACS DATABASE ERROR
Nozzle MACS database number for the
following nozzle is not correct.
-Check the database number in [Machine]
- [Setting] - [Machine Data] - [Precision] -
[Pickup MACS] - [Nozzle MACS] -
[Database No.].
-Check the accessible to the database.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50177
17/23
5. Limitations
5.1. Feeder MACS
Target machine is a mounter equipped with SS Feeder. Machines without SS Feeder
and other series of mounters are not supported.
Target feeder type is 4mm feeder and 8mm feeder.
CT estimation of optimizer doesn’t consider the operation time of this function.
5.2. Nozzle MACS
Both of 311A nozzle with two holes and 311A nozzle with one hole can’t be used in one
machine. Select either one.
Target nozzle is 30X type and 31X type.
FNC nozzle system is not supported.
CT estimation of optimizer doesn’t consider the operation time of this function.
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50177
18/23
6. Appendix
6.1. Setting method of Feeder MACS mark data
As described on [4.1.3. Mark data of Feeder MACS], to execute Feeder MACS, you need to
register the special mark data into the database, and set the database number.
It is possible to create mark data, but we recommend use the one enclosed in the installation
CD. Setting method is as follows.
(1) Copy [PickUpMACS_DATA.ygx] from the installation CD to the [No1] folder of the target
machine.
(2) Read board data [PickUpMACS_DATA.ygx] on the [Setup] screen. Sometimes a board
data read error occurs, but ignore it.
(3) Press the [Mark] button. Select mark data named [Feeder MACS]. And press the
[Database] button.