ERR-LIST-ACM.pdf

Number Error Text Alternate Title Desc Cause errortxt 100 Illegal requested number of boards The requested number of boards must be at least 1. - Number of boards not correct. - Change the number of boards. 101 Order doe…

100%1 / 52
Number Error Text Alternate Title Desc Cause errortxt
100 Illegal requested number of boards
The requested number of boards
must be at least 1. - Number of boards not correct. - Change the number of boards.
101
Order does not exist
There is no existing order name.
- An order name is required.
- Enter an existing order name.
102 Invalid serial number range
The serial numbers must be
correctly formatted and the ranges
are not allowed to overlap.
103 Invalid changeover method Invalid changeover method. - This is a software error. The function is not yet implemented. - Report error to your service representative.
104 Invalid order start count
The starting count must be al least
1. - Change the starting count.
105
Board in work-area uses different
action spec
The requested action can not be
executed because the board in the
work-area requires a different
action spec from the one
specified.
- Abort the current board and retry the operation, or
- Finish the production of the board in the work-area before starting a new
action spec.
106 Invalid selection state
executed on the selected order
because of an invalid selection
state.
107 Illegal abort action
Machine must be stopped before
production may be aborted.
- Stop the production, by pressing the STOP button.
- Retry the abort function.
108 Machine not in stopped state
Machine must be stopped to
execute the requested action.
- Stop the production, by pressing the STOP button.
- Retry the action.
109 Order creation failed
The system cannot create the
order. - Incorrect data entered. - Check if all entered parameters are correct.
110
Maximum number of orders
exceeded
The maximum number of orders
that the system can handle, has
been reached. - Too many orders in the system.
- Delete one or more orders.
- Retry the creation of the order.
111 No order available
The system requires an order,
before this action is possible. - No order present.
- Create an order.
- Retry the action.
112
Errors in action spec parsing and
validation
The action spec used in the order
contains errors or does not match
the machine configuration.
- Incorrect syntax in action spec.
- Mismatch between machine configuration and action spec.
- Inspect the error messages that have been added to the action spec.
- Correct the action spec.
- Adjust the machine configuration.
- Try to re-enter the order.
114 Duplicate order name found
The name entered for the order
already exists. - A unique name is required. - Use a different order name.
115 Order has already completed
The order can not be executed
because the complete number of
boards is already executed.
- Modify number of board's of this order.
- Create new order with same action spec.
116 Order is in use
The order is used by one or more
boards in the machine. - It is not allowed to perform this action.
118
Usage of gripper with adapted
support height needed for
component %1
This odd component has to be
handled by a gripper with an
extended support-height, to avoid
collision with the Fiducial camera.
- This component is too large to be able to rotate it in the area
near the FA-camera and the z-guidance.
- Make sure this component is handled by a gripper with an extended support-
height, so when the head is in the upper position the top side of the component
will not collide with the FA-camera or the Z-guidance of the head.
119
Component %1 can collide with an
obstacle in the work area.
Possible
collision of
component
%1 with e.g.
top plate of
feeder trolley
During handling of the component
it may collide with a high obstacle
in the work area.
- This component must be handled with an extended gripper,
therefore the lowest parts of the component may collide with
high obstacles in the work area. - Verify that no such collision can occur.
120
Global fiducial %1 not measured
before first reference
The placement of a component is
corrected for deviations in the
board position. This is calculated
with the global fiducial alignment
correction matrix specified for the
component. The indicated fiducial
is not measured before the first
placement of a com
- There is no fiducial detection action for the indicated fiducial in
the action spec before the first placement of a component that
uses the fiducial correction matrix in which this fiducial is used. - Modify the action spec.
121
Unable to execute the order
related command - A similar command is currently being executed - Wait till the current command is executed and then try again
122
Order on machine already exists,
use a different name.
The name entered for the order to
be created for the process
program being downloaded from
the Host already
exists on the machine. - A unique name is required. - Use a different order name.
123
Action spec on machine already
exists, use a different name.
The name entered for the action
spec. to be created for the process
program being downloaded from
the Host already
exists on the machine. - A unique name is required - Use a different action spec. name.
124
Operational failed because GEM is
not operational
The requested operation could not
be performed because GEM is not
operational. GEM is not installed or there is no communication with GEM Ensure that GEM is installed and that communication is up and try again
125
Requested operation failed
because specified order does not
exist
Requested operation failed
because specified order does not
exist
- In case of upload operation the specified order does not exist
on the machine
- In case of downlad operation the specified order does not
exist on the HOST Select or specify a different order
126 The operation failed
The process program upload or
download operation failed. Unknown Try again
200 Unknown error detected
The occurred error is unknown to
the system. - Mismatch between controllers or software layers.
- Report error to your service representative.
- Make a logdisk as described in the Service Manual.
201 Illegal recovery action
The selected recovery action can
not be applied for this kind of error. - Wrong display of possible recovery actions. - Try another recovery action.
202
Fail to start transport for error
recovery
An attempt to start the transport
during an error recovery action
failed. - No servo power present. - Switch on servo power.
203 Unknown warning The warning is not specified yet. - Report error to your service representative.
204
Unknown error reported by the
system The error is not defined yet.
- An error was detected which is unknown to the human
interface.
- Retry and continue.
- Report error to your service representative.
205 %1 :\tUnknown warning The warning is not defined yet.
- A warning was detected which is unknown to the human
interface.
- Retry and continue.
- Report warning to your service representative.
206 Undefined process error
The process error is not defined
yet.
- Retry and continue.
- Report error to your service representative.
207 Retry action failed The retry action is unsuccessful. - A machine or process error occurs during the retry action.
- Check error cause and solve error.
- Retry and continue.
- If the retry action still fails, restart the system and report error to your service
representative.
208 Error reason unknown
The process controller signalized
errors, but no errors where
reported, so the reason of the
error is unknown.
- Continue
- Report error to your service representative.
209
Requested function can not be
executed.
The requested function
(Calibration) can not be executed
in this machine state.
- A board is present in the machine.
- An error is not solved on the machine
- Solve error (skip board).
- Remove board out of machine (skip board or using run-out function).
210
Sorry, this function (%1) has not
been implemented (yet)
A function was activated that has
not been implemented in the
current software version.
- Functions that are not complete yet, should not be accessible
for the user.
- By mistake, this function is reachable for the user.
- Clear the error, and do not use the function again, you should not be needing
it.
- Report error to your service representative.
211
System communication error on:
%1
An unexpected system error
occurred.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
212 Communication failure in system
A communication error has been
occurred between the system
controller and the process
controller.
- No connection between the two systems.
- Malfunctioning network card on either system.
- A software problem in the machine.
- Check the coax cable connection between the two systems.
- Check the proper working of the network cards (using diagnostic software).
- Restart the system.
- Report error to your service representative.
213
Single step during error recovery
finished, press retry to resume
The machine is in step mode an
has finished a single step during
the retry of an error. - Press retry again to proceed with the next step in recovering the error.
214 Machine failure An unexpected situation occurred.
- Make a logdisk as described in the Service Manual.
- Restart the system.
- Report error to your service representative.
215
No extra information available