ERR-LIST-ACM.pdf - 第50页

3224 %1 : No parts available of selected die type Wafer handler feedsection cannot offer the requested dies No pickable dies of the required type left on the wafer(s) - Replace the empty or bad wafer(s) in the wafer hand…

100%1 / 52
3214 %1 :\tFeedback error lift The lift servo loop is not closed.
- Defective cabling to motor or encoder.
- Defective motor or encoder.
- Defective motor controller.
- Defective driver board Check possible causes.
3215 %1 :\tFeedback error puller The puller servo loop is not closed.
- Defective cabling to motor or encoder.
- Defective motor or encoder.
- Defective motor controller.
- Defective driver board. Check possible causes.
3216 %1 :\tFeedback error snapin The snapin loop is not closed.
- Defective cabling to motor or encoder.
- Defective motor or encoder.
- Defective motor controller.
- Defective driver board. Check possible causes.
3217 %1 :\tCarrier not safe for move lift
Carrier is not positioned well on
the lift, after the carrier was in the
position to pick components out of
it.
- Carrier lost from puller tip.
- Sensor B3 not well adjusted. Check state of puller tip.
3218
%1 : Wafer handler
communication error
Error communicating with wafer
handler feedsection
- Hadware or software connection error
- Communication protocol error
- Check RS 232 connection between wafer handler section and machine
- Check communication port configuration
- Retry the operation
- If not correct, contact your service representative
3219 %1 : Wafer handler data error
Invailid message data for the
wafer handler feedsection is sent
or received
Communication protocol error, the data does not comply with
the communication interface of the wafer handler section
- Make a logdisk as described in the Service Manual
- Report error to your service representative
3220
%1 : Wafer handler command
failure
Reply message data of wafer
handler feedsection data indicates
operation failure Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, make a logdisk as described in the Service Manual
- Restart the system
3221
%1 : Wafer handler servo power
failure
Servo power of wafer handler
feedsection can't be turned on/off Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, restart the system
3222
%1 : Unable to remove wafer while
homing all wafer handler axes
Wafer handler feedsection cannot
home all axes Selected wafer cannot be removed
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, restart the system
3223
%1 : Unsafe to home all wafer
handler axes
Wafer handler feedsection cannot
home all axes It is not safe now to home all the wafer handler's axes
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, restart the system
3224
%1 : No parts available of selected
die type
Wafer handler feedsection cannot
offer the requested dies No pickable dies of the required type left on the wafer(s)
- Replace the empty or bad wafer(s) in the wafer handler cassette
- Retry the operation
3225
%1 : Operational wafer handler
error
A machine malfunction occurred
on the wafer handler feedsection Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, make a logdisk as described in the Service Manual
- Restart the system
3226
%1 : Unable to home wafer
handler axes
Wafer handler feedsection cannot
home all axes Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, restart the system
3227
%1 : Wafer handler die setup
changeover failed
Wafer handler feedsection does
not accept current die setup
- Wafer handler is in wrong state
- Invalid die setup in action spec of current order
- Check wafer handler module for errors, warnings, etc.
- Check die setup in machine action spec
- Retry the operation
3228
%1 : Unable to enter normal offline
state on wafer handler
Not possible to change the wafer
handler state to OFFLINE -
NORMAL Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
3229
%1 : Unable to enter abnormal
offline state on wafer handler
Not possible to change the wafer
handler state to OFFLINE -
ABNORMAL Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
3230
%1 : Unable to enter normal
production state on wafer handler
Not possible to change the wafer
handler state to PRODUCTION -
NORMAL Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
3231
%1 : Unable to enter dry
production state on wafer handler
Not possible to change the wafer
handler state to PRODUCTION -
DRY Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
3232
%1 : Unable to shutdown wafer
handler
Waffer handler feed section does
not accept shutdown command Wafer handler is in wrong state
- Check wafer handler module for errors, warnings, etc.
- Retry/skip the operation
3233
%1 : Wafer handler not able to
prepare requested dies
Production cycle command ( Pick
Die ) cannot be executed by wafer
handler
Wafer handler is in wrong state or its production sequence is
not correct
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, make a logdisk as described in the Service Manual
- Restart the system
3234
%1 : Wafer handler not able to
transfer requested shuttle
Production cycle command (
Request Die ) cannot be executed
by wafer handler
Wafer handler is in wrong state or its production sequence is
not correct
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, make a logdisk as described in the Service Manual
- Restart the system
3235
%1 : Wafer handler not able to
release requested dies
Production cycle command (
Release Die ) cannot be executed
by wafer handler
Wafer handler is in wrong state or its production sequence is
not correct
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, make a logdisk as described in the Service Manual
- Restart the system
3236
%1 : Wafer handler not able to
finish shuttle
Production cycle command ( Die
Transfer Complete ) cannot be
executed by wafer handler
Wafer handler is in wrong state or its production sequence is
not correct
- Check wafer handler module for errors, warnings, etc.
- Retry the operation
- If not correct, make a logdisk as described in the Service Manual
- Restart the system
3237 %1:\t No duplo nozzle attached
The current attached toolbit is no
duplo nozzle
- An attempt was made to use an inner nozzle, the current
toolbit however has no inner nozzle - Correct action spec
3238 %1 :\tZ-position tolerance Z calibration is out of tolerance. - The measured Z-level is out of tolerance - Check module Z-level
3239
Feeder position: %1\x0A
3240
RETRY
INFORMATION\x0AFeeder
position: %1\x0A
3300
RVS :\tSetup error for feeder
%1.%2
RVS detected a mismatch
between current feeder setup and
setup requested by action spec - A new order with different action spec is started.
- Place requested feeders on requested positions.
- Go to RVS and select 'setup - running order'
3301
RVS :\tFeeder %1.%2 (%3) is
empty!
A feeder has run out of
components. - The feeder is not refilled in time. - Refill feeder.
3302
RVS :\tVerification in progress
RVS is verifying the setup.
- Try again in a few moments.
3303
RVS :\tEmpty feeder inserted on
feeder %1.%2
A feeder with actual quantity=0
inserted. - Feeder quantity is zero. - Refill feeder.
3304 RVS :\tSetup needed
RVS needs to be activated to
perform a setup. - Activate RVS-setup.
3305
RVS :\tFeeder %1.%2 was
removed
A feeder used by a running order
was removed. - Operator action. - Put feeder back in system.
3306
RVS :\tFeeder with wrong
component inserted on %1.%2
(%3 expected)
A feeder was inserted with the
wrong components on it. - Operator action. - Replace components with correct ones.
3307
RVS :\tFeederbank %1 was
removed
A feederbank, which is currently
used by an order, was removed. - Operator action. - Put removed feederbank back in machine.
3308 RVS :\tSMF local directory is full SMF local directory is full.
3309 RVS :\tUndefined error The RVS error is not defined yet.
- Retry and continue.
- Report error to your service representative.
3310 RVS :\tUndefined warning
The RVS warning is not defined
yet.
- Retry and continue.
- Report warning to your service representative.
3311 The error recovery action failed.
One or more errors (possible the
same one(s) as the original
one(s)) occurred during the error
recovery action. - Recover again.
3350
RVS :\tFeeder %1.%2 (%3) almost
empty!! (Quantity: %4)
The specified feeder is almost