1001 Machine is not empty The machine was unable to change the simulation mode, since one or more boards are present in the machine. - One or more boards are present in the machine. - Abort the production and restart, th…

100%1 / 52
722 Cannot learn CA package
Cannot learn specified CA
package. - See detailed error cause. - Modify description and retry.
723 Cannot teach FA package
Cannot teach light settings for
specified FA package - See detailed error cause -
800
Incorrect machine setup
Machine setup not OK.
- Verify machine setup.
801
The feeder from section '%1' with
feedernr. '%2' and channelnr. '%3'
from current action spec is
disabled The feeder is disabled. - Try to enable the feeder.
802
The coplanarity checker actions
are disabled
The coplanarity checker is
disabled for performance reasons.
803 Transport width check failed
The current transport width does
not equal the required transport
width for the current order.
- The current transport width is not know by the transport
system.
- The current transport width is wrong. - Adjust transport width, and if it is correct then verify it manually.
804
Feeder check failed, not all
required feeders are enabled
Feeder setup check fails, because
not all required feeders are
enabled.
- The feeder setup has not been verified.
- One or more required feeders are disabled.
- Check the feeder setup, and if it is correct verify it manually.
- Enable the required feeders.
805
Not all required toolbits are in
correct heads
One or all required toolbits for the
current order are not present in the
heads used by that order.
- The heads, used by the current order, are not containing the
correct toolbits.
- Check if all heads contain the correct toolbit, when it is correct then verify the
setup manually.
806
Not all required toolbits are
present on the machine
The required toolbits are not on
the machine available. - Supply the required toolbits.
807
Support plate check failed
- Check the support plate.
808 Setup Control System check failed
The setup control system reports
an error when it was checking the
setup of the machine.
- The setup of the machine is not equal to the required setup for
the current order. - Check the setup of the machine, and if it is correct verify it manually.
809
Toolbit '%1' from current action
spec is not on the machine - Put the missing toolbits in the toolbit exchange units or in the heads.
810
No empty positions left in the
toolbit exchange units
- Remove a toolbit, that is not required for current action spec, from the toolbit
exchange unit(s).
811
Head nr '%1' should carry toolbit
'%2' but carries '%3'.
- The heads don't carry the toolbits as they are required by
current action spec. - Change toolbits.
812
Can't find requested feeder with
number '%1' and channel '%2'
The requested combination of
feeder number and feeder channel
was not found. - Change feeder(s).
813 Error not yet specified
The detected error is not yet
specified.
- Retry the action.
- Report error to your service representative.
900 MIS data lost
The MIS data storage failed, no
MIS data is stored by the system.
The MIS data for this order period
is not reliable.
- Disk full.
- Illegal file modifications by user.
- The order has been aborted before the first board has entered
the machine. - Check disk capacity.
1000 Errors exist on the machine
Unable to modify the configuration
because one or more errors are
pending. - Solve current existing errors or abort the production and retry.
1001 Machine is not empty
The machine was unable to
change the simulation mode, since
one or more boards are present in
the machine. - One or more boards are present in the machine.
- Abort the production and restart, then try again.
- Activate the run-out restart the production, when the machine is empty and
stopped, then try again.
1002
No reject belt configured for
REUSE components
Although the action spec refers to
components with dump method
REUSE, no reject belt is
configured on the machine. If a
REUSE component has to be
dumped, it will be dumped in one
of the dump baskets.
- One of the vision files referred to by the action spec defines
dump method REUSE. However there is no dump location for
REUSE components defined in the configuration of the
machine.
- Either configure a reject belt , modify the vision files with dump method
REUSE or ignore this warning.
1003
No dump basket configured for
WASTE components
Although the action spec refers to
components with dump method
WASTE, no dump basket is
configured on the machine. If a
WASTE component has to be
dumped, it will be dumped on the
reject belt.
- One of the vision files referred to by the action spec defines
dump method WASTE. However there is no dump location for
WASTE components defined in the configuration of the
machine.
- Either configure a dump basket, modify the vision files with dump method
WASTE or ignore this warning.
1004 Can not read gripper file '%1'
Can not read the specified gripper
file because it is not on the
machine or transfer failed.
- The file is not on the machine.
- There has been an internal communication error.
- Install the file on the machine.
- Retry the action. If the problem persists, contact your service representative.
1005 Can not write gripper file '%1'
Can not write the specified gripper
file because it is not on the
machine or transfer failed.
- The file is not on the machine.
- There has been an internal communication error.
- Install the file on the machine.
- Retry the action. If the problem persists, contact your service representative.
1006
Unable to process state change
command - A similar command is currently being executed - Wait till existing command is executed and then try again
1100 Cannot remove file '%1'
Cannot remove a file from the
system.
- File is write-protected.
- Filesystem is corrupted.
- Problem in the Control Software.
- Remove the write protection attribute of the file.
- Repair the filesystem.
1101
An error occurred during
production
An error occurred during the
processing on the process
controller.
- Retry and continue.
- Restart the system.
- Report error to your service representative.
1102
Cannot save action spec under
name '%1'
Cannot save action spec under the
current name. - Try to save it with another name.
1103
Cannot update pick position
Cannot update pick position.
- Check if pick position is valid.
1104
Cannot update place position for
component '%1'
Cannot update place position for a
component. - Check if place position and component are valid.
1105 No current action spec is loaded No current action spec is loaded. - No current action spec is loaded. - Load action spec.
1106
Cannot update pick position
- Cannot update pick position
- Unknown
-
1200 Unable to set specified date/time
It was not possible to modify the
machine's date/time. It remains
unchanged.
- The date/time specified may be incorrect.
- The state of the machine does not allow the date/time to be
changed.
- Correct specified date/time and try again.
- Try again at a later time.
1201
Backup of machine data failed for
directory: %1
The data could not be copied to
the diskette.
- Unreadable files on the system.
- Write-protected diskette.
- Repair the filesystem.
- Open write protect tab of diskette.
1202 No diskette present No diskette is in the drive.
- No diskette in the drive.
- Defective drive.
- Insert diskette in drive.
- Contact your service representative for repairs.
1203 Diskette is write protected
The diskette is protected against
writing. - The write-protect tab is enabled.
- Disable the write-protection switch on the diskette and retry the action. Be
careful! There might be important data on the diskette.
1204
Disk is full during backup of
directory: %1 The diskette is full.
- Too many files were on the diskette before the backup began.
- The data to be backed up is too large.
- Use an empty diskette for the backup, try again.
- There is an abnormal amount of data to be backed up, warn your service
representative.
1205 Can't remove file or directory %1
The file or directory cannot be
removed. - Diskette may be corrupted or unformatted.
- Try to repair the diskette, using 'CHKDSK A:' on an MSDOS PC.
- Format the diskette.
1206 The beeper is disabled The beeper is disabled. - The configuration data disabled the beeper. - Modify configuration file (See manual).
1207 Restore XY data failed
Failed to restore XY data: transfer
of (one of the) data files to the
aPC has failed.
- Connection between SC and aPC not OK.
- One or more of the data files to restore are damaged.
- The diskette was removed before all files were transferred.
- Restart the machine.
- Use valid data files.
- Leave the diskette in the drive until the restore has finished.
1208
Function cannot be executed in
this state
The SC or aPC is not in a state in
which restoring XY calibration data
is allowed. - There are active orders. - Remove the orders.
1209
Unable to set the machine date
and time - A similar command is currently being executed - Wait till the current command is executed and then try again
1300
Dump position %1 is not defined in
the APC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1301
Dump position %1 is not defined in
the SC configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1302
Head %1 is not defined in the SC
configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1303
Head %1 has conflicting types in
SC (%2) and APC (%3)
configuration
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.
1304
Head %1 is not defined in the APC
configuration file
A conflict is detected in the
administration configuration files.
(System controller and process
controller files) - Illegal update of these configuration files. - Re-configure item.