708 Cannot delete BM package '%1' Cannot remove BM package from the machine. - The package is not on the machine. - The package is not in the index file. - There has been an internal communication error. - Retr…

100%1 / 52
647 %1 :\tDump full
There is no more space on the
reuse dump to put components
on. - Many components have been dumped on the reuse dump. - Empty the reuse dump unit.
648
Feeder Section %1 :\tRepicks
exceeded, picks from Feeder %2,
channel %3 redirected to alternate
tape feeder
The system is switching to an
alternate feeder.
- Feeder is empty.
- There is an error occurred on feeder.
- Refill feeder.
- Replace feeder.
649
Transport :\ttimeout occurred
during lift calibration
The lift calibration has a time-out;
lift calibration is automatically
initiated by the system when the
transport is started. - The movement class for transport lift calibration is too slow. - Adjust the movement class for transport lift calibration.
650 %1 :\tInvalid force specified
The requested force cannot be
applied with the current toolbit. - Wrong toolbit or wrong force specified. - Change toolbit or change force.
700
Cannot read CA package '%1'
because it is not on machine, or
ftp error
Cannot read the specified CA
package because it is not on the
machine or transfer failed.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
701
Cannot read FA package '%1'
because it is not on machine, or
ftp error
Cannot read the specified FA
package because it is not on the
machine or transfer failed.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
702
Cannot read BM package '%1'
because it is not on machine, or
ftp error
Cannot read the specified BM
package because it is not on the
machine or transfer failed.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
703
Cannot delete CA package '%1'
because it is still used
Cannot delete CA package
because it is still used. - Order is still in use. - Wait until order is deleted.
704
Cannot delete FA package '%1'
because it is still used
Cannot delete FA package
because it is still used. - Order is still in use. - Wait until order is deleted.
705
Cannot delete BM package '%1'
because it is still used
Cannot delete BM package
because it is still used in action
specifications. - Order is still in use. - Wait until order is deleted.
706 Cannot delete CA package '%1'
Cannot remove CA package from
the machine.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error. - Retry the action.
707 Cannot delete FA package '%1'
Cannot remove FA package from
the machine.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error. - Retry the action.
708 Cannot delete BM package '%1'
Cannot remove BM package from
the machine.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error. - Retry the action.
709 Cannot read CA package '%1'
Cannot read the specified CA
package.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
710 Cannot read FA package '%1'
Cannot read the specified FA
package.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
711 Cannot read BM package '%1'
Cannot read the specified BM
package.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
712 Cannot delete CA package '%1'
Cannot delete CA specified
package. - Illegal modification of the package. - Re-install package(s).
713 Cannot delete FA package '%1'
Cannot delete FA specified
package. - Illegal modification of the package. - Re-install package(s).
714 Cannot delete BM package '%1'
Cannot delete Bad mark specified
package. - Illegal modification of the package. - Re-install package(s).
715 Cannot write CA package '%1'
Cannot write the specified CA
package.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
716 Cannot write FA package '%1'
Cannot write the specified FA
package.
- The package is not on the machine.
- The package is not in the index file.
- There has been an internal communication error.
- Install the package on the machine.
- Retry the action. If the problem persists, contact your service representative.
717 Cannot write BM package '%1'
Cannot write the specified BM
package.
- The package is not on the machine
- The package is not in the index file
- There has been an internal communication error
- Install the package on the machine
- Retry the action. If the problem persists, contact your service representative.
718 Cannot measure CA package '%1'
Cannot measure specified CA
package. - See detailed error cause. - Modify description and retry.
719 Cannot measure FA package '%1'
Cannot measure specified FA
package. - See detailed error cause. - Modify description and retry.
720 Cannot measure BM package '%1'
Cannot measure specified BM
package. - See detailed error cause. - Modify description and retry.
721 Cannot draw CA definition Cannot draw the CA definition. - Illegal modification of the package. - Re-install package(s).
722 Cannot learn CA package
Cannot learn specified CA
package. - See detailed error cause. - Modify description and retry.
723 Cannot teach FA package
Cannot teach light settings for
specified FA package - See detailed error cause -
800
Incorrect machine setup
Machine setup not OK.
- Verify machine setup.
801
The feeder from section '%1' with
feedernr. '%2' and channelnr. '%3'
from current action spec is
disabled The feeder is disabled. - Try to enable the feeder.
802
The coplanarity checker actions
are disabled
The coplanarity checker is
disabled for performance reasons.
803 Transport width check failed
The current transport width does
not equal the required transport
width for the current order.
- The current transport width is not know by the transport
system.
- The current transport width is wrong. - Adjust transport width, and if it is correct then verify it manually.
804
Feeder check failed, not all
required feeders are enabled
Feeder setup check fails, because
not all required feeders are
enabled.
- The feeder setup has not been verified.
- One or more required feeders are disabled.
- Check the feeder setup, and if it is correct verify it manually.
- Enable the required feeders.
805
Not all required toolbits are in
correct heads
One or all required toolbits for the
current order are not present in the
heads used by that order.
- The heads, used by the current order, are not containing the
correct toolbits.
- Check if all heads contain the correct toolbit, when it is correct then verify the
setup manually.
806
Not all required toolbits are
present on the machine
The required toolbits are not on
the machine available. - Supply the required toolbits.
807
Support plate check failed
- Check the support plate.
808 Setup Control System check failed
The setup control system reports
an error when it was checking the
setup of the machine.
- The setup of the machine is not equal to the required setup for
the current order. - Check the setup of the machine, and if it is correct verify it manually.
809
Toolbit '%1' from current action
spec is not on the machine - Put the missing toolbits in the toolbit exchange units or in the heads.
810
No empty positions left in the
toolbit exchange units
- Remove a toolbit, that is not required for current action spec, from the toolbit
exchange unit(s).
811
Head nr '%1' should carry toolbit
'%2' but carries '%3'.
- The heads don't carry the toolbits as they are required by
current action spec. - Change toolbits.
812
Can't find requested feeder with
number '%1' and channel '%2'
The requested combination of
feeder number and feeder channel
was not found. - Change feeder(s).
813 Error not yet specified
The detected error is not yet
specified.
- Retry the action.
- Report error to your service representative.
900 MIS data lost
The MIS data storage failed, no
MIS data is stored by the system.
The MIS data for this order period
is not reliable.
- Disk full.
- Illegal file modifications by user.
- The order has been aborted before the first board has entered
the machine. - Check disk capacity.
1000 Errors exist on the machine
Unable to modify the configuration
because one or more errors are
pending. - Solve current existing errors or abort the production and retry.