ERR-LIST-ACM.pdf - 第28页

2217 %1 :\tComponent Mismatch (Number of leads) Mismatch between the component description and the measured component charateristics. Number of leads - Wrong component attached - Wrong component description used. - Bad c…

100%1 / 52
2208 %1 :\tCA marker distortion
The corner marker on the
calibration plate can not be
detected reliably.
- One or more marker images are slightly distorted.
- Not enough light to detect the markers.
- Interference from environmental light conditions.
- Clean marker plate.
- Increase light level.
- Limit environmental light.
2209 %1 :\thead marker displacement
The currently detected head
marker position differs too much
from the calibrated position.
- Not correctly connected FA camera
- Not correctly mounted calibration plate or CA unit - Check connections of FA camera and CA calibration plate.
2210 %1 :\thead marker distortion
The head marker is distorted
(dust). - Dust on the head marker. - Clean calibration plate.
2211 %1 :\tGeneral SBIP data error
Object (fiducial or bad mark)
identification not known at SBIP
level.
The fiducial or bad mark description has not been downloaded
to SBIP properly. This is leading to false data access.
- Modify package data and save (again).
- Retry and continue.
- Make a logdisk as described in the Service Manual.
- Restart the system.
- Report error to your service representative.
2212 %1 :\tComponent not measured Error in system call sequence - Bad processing sequence
- Retry action
- Report error to your service representative.
2213 %1 :\tFiducial not measured
The fiducial could not be
measured by the vision system.
- No fiducial has been found.
- Bad colour (polarity) of fiducial (Black or White).
- Wrong light level.
- Check the fiducial by using the setup vision menu, to see if the light level and
the polarity are correctly specified in the fiducial file.
- Check if the board is stopped on the correct position in the transport system.
- Re-position FA camera (by ad
2214
%1 :\tFirst component lead not
found
The first lead, used as reference,
can not be detected.
- Wrong component attached.
- Wrong component description used.
- Wrong index feeder for tape components.
- Wrong pitch tray for tray components.
- Orientation of the component in feeder not correct.
- Bad contrast
- Verify component and component description by SHOW function, check reject
level !
- Check index of the feeder.
- Check the pitch of the tray with the one specified in the action spec.
- Check the orientation of the component in the feeder with the on
2215
%1 :\tComponent mismatch
(second lead)
Mismatch between the component
description and the measured
component characteristics.
(Second lead).
- Wrong component attached.
- Wrong component description used.
- Wrong pick-up position.
- Verify component and component description by SHOW function.
- Check the pick-up position.
2216
%1 :\tComponent Mismatch
(Number of leads)
Mismatch between the component
description and the measured
component characteristics.
Number of leads
- Wrong component attached
- Wrong component description used.
- Bad contrast
- Component is damaged.
- Verify component and component description by SHOW function.
- Change illumination level or type
- Change threshold
- Change ruler offset or width
2217
%1 :\tComponent Mismatch
(Number of leads)
Mismatch between the component
description and the measured
component charateristics.
Number of leads
- Wrong component attached
- Wrong component description used.
- Bad contrast
- Component is damaged.
- Verify component and component description by SHOW function.
- Change illumination level or type
- Change threshold
- Change ruler offset or width
2218 %1 :\tLead spacing not correct.
Mismatch between the defined
lead spacing and the measured
lead spacing.
- Wrong component attached.
- Wrong component description used.
- Bended leads.
- Verify component and component description by SHOW function.
- Check for bended leads.
2219 %1 :\tLead width not correct
Mismatch between the defined
lead width and the measured lead
width.
- Wrong component attached.
- Wrong component description used. - Verify component and component description by SHOW function.
2220 %1 :\tComponent leads skewed.
The lead skewing is out of
tolerance. - Component leads are skewed.
- Verify component and component description by SHOW function.
- Switch off skew option.
2221 %1 :\tLead end not found.
The component lead end can not
be found.
- Wrong component attached.
- Wrong component description used, modify lead end
parameter. - Verify component and component description by SHOW function.
2222 %1 :\tFiducial size not correct
Mismatch between measured
fiducial size and described size.
- Bad fiducial.
- Wrong description.
- Check fiducial.
- Modify description.
2223
%1 :\tComponent can not be
recognized Component can not be found
- Wrong component attached
- Wrong component description used.
- Bad contrast, image too dark
- Verify component and component description by SHOW function.
- Change illumination level or type
2224
%1 :\tSide on verification set not
measured
The defined side can not be
measured.
- Displacement too big
- Wrong measurement position - Check proper functioning of the verification set
2225
%1 :\tNot able to detect a bad
mark Not able to detect any bad mark. - Fiducial/Bad Mark camera not above bad mark.
- Move camera above bad mark.
- Modify light levels of bad mark description.
- Adapt action-spec. for bad mark location.
2226
%1 :\tComponent Mismatch
(sides)
Mismatch between the component
description and the measured
component characteristics.
Distance between the sides - Wrong component description used. - Verify component and component description by SHOW function.
2227
%1 :\tError reading vision package
(.CA, .FA, .BM)
The specified package is not
installed on the system. - Illegal modification on the system.
- Re-install vision images.
- Add specific vision image.
2228
%1 :\tLight calibration not
successfully completed Light calibration failed.
- Corner markers CA calibration plate are not clearly visible.
- Placement head positioning above CA camera not correct.
- Clean CA calibration plate (possibly also bottom side...).
- Check visibility and contrast of corner markers in image with lowered head.
2229 The nozzle is polluted or worn out
The nozzle is either polluted or
worn out.
- Clean the nozzle.
- Replace the nozzle.
2230
Component light-level teaching
failed
Component light-level teaching
failed.
- The component above the CA camera differs from the
specified component.
- Initial light level is not correct.
- Check component.
- Check initial light level of component.
2300 %1 :\tNot squared
The square EPDs on the Y2 axis
indicate a position difference of
more then 20 mm between the
axes Y1 and Y2.
- This error could be caused by another error (e.g. position
error Y1 or Y2).
- After initialization the offset data in HDV.CFG is not correct.
- Check for other related errors and solve them.
- Check offset data for Y1 and Y2 in HDV.CFG. This data should be refreshed
on every homing action.
2301
%1 :\tNo servo-power
No servo power available.
- Servo power off.
- Switch on servo power.
2302 %1 :\tQuickstop
A quickstop was activated due to
an unsafe situation on the
machine.
- One of the heads is not in a safe position during XY-
movement, due to a servo problem.
- One of the covers has been opened during movement of the
machine.
- Check servo-system of the head causing the emergency input active.
- Close the cover, and retry the action.
2303
%1 :\tLIMMS error
A (low) grade error is signalized.
See Service Manual.
See Service Manual.
2304 %1 :\tFatal LIMMS error
A serious error has been reported
by an axis. See Service Manual. See Service Manual.
2305
%1 :\tAlignment error
Error during magnetic alignment.
See Service Manual.
See Service Manual.
2306 %1 :\tHome-search error
The home position is not found.
This error is detected by LAPI.
- Communication failure between LAPI and axis.
- The error could be caused by a servo error (e.g. 'home-search
error 2336').
- Check for other errors and solve them.
- Retry operation.
- If problem still persists, contact your service representative.
2307 %1 :\tAxis connect error Unable to connect axis by CAN. - Malfunction of the CAN-bus network. - Check the CAN-bus network.
2308 %1 :\tI/O-Handler download error
I/O handler program in the Y2 axis
could not be downloaded.
- The I/O handler program as defined in HDV.CFG could not be
found.
- LAPI function 'LsdlohDownload' failed. - Contact your service representative.
2309 %1 :\tI/O-Handler activate error
I/O handler program in the Y2 axis
could not be started. - LAPI function 'LsdlohActivate' failed. - Contact your service representative.
2310 %1 :\tAxis initialization error Not able to initialize H-drive. - LAPI function 'SacInitialize' failed. - Contact your service representative.
2311 %1 :\tLAPI init Error initializing LAPI layer.
- Initialization file CALSTART.CFG was not found or is
erroreous. - Contact your service representative.
2312 %1 :\tNot all axes found
At startup of the aPC, during the
search over the CAN bus, not all
axes were found.
- CAN-address on the LAC is set to faulty.
- The range of network addresses to scan for is not correct.
- Defective LAC.
- Defective CAN-bus connection.
- Check CAN-addresses on the LAC.
- Check the range of network-adresses to scan for in CALSTART.CFG.
- Check CAN-bus connections.
2313 %1 :\tMeasurement alarm
The signal level of the
measurement system is too low.
- Filthiness of linear scale or measuring head.
- Alignment of measuring head to linear scale not correct.
- Clean linear scale and measuring head.
- Check alignment of measuring head to the linear scale.
- Retry action.