ERR-LIST-ACM.pdf - 第29页
2300 %1 :\tNot squared The square EPDs on the Y2 axis indicate a position difference of more then 20 mm between the axes Y1 and Y2. - This error could be caused by another error (e.g. position error Y1 or Y2). - After in…

2217
%1 :\tComponent Mismatch
(Number of leads)
Mismatch between the component
description and the measured
component charateristics.
Number of leads
- Wrong component attached
- Wrong component description used.
- Bad contrast
- Component is damaged.
- Verify component and component description by SHOW function.
- Change illumination level or type
- Change threshold
- Change ruler offset or width
2218 %1 :\tLead spacing not correct.
Mismatch between the defined
lead spacing and the measured
lead spacing.
- Wrong component attached.
- Wrong component description used.
- Bended leads.
- Verify component and component description by SHOW function.
- Check for bended leads.
2219 %1 :\tLead width not correct
Mismatch between the defined
lead width and the measured lead
width.
- Wrong component attached.
- Wrong component description used. - Verify component and component description by SHOW function.
2220 %1 :\tComponent leads skewed.
The lead skewing is out of
tolerance. - Component leads are skewed.
- Verify component and component description by SHOW function.
- Switch off skew option.
2221 %1 :\tLead end not found.
The component lead end can not
be found.
- Wrong component attached.
- Wrong component description used, modify lead end
parameter. - Verify component and component description by SHOW function.
2222 %1 :\tFiducial size not correct
Mismatch between measured
fiducial size and described size.
- Bad fiducial.
- Wrong description.
- Check fiducial.
- Modify description.
2223
%1 :\tComponent can not be
recognized Component can not be found
- Wrong component attached
- Wrong component description used.
- Bad contrast, image too dark
- Verify component and component description by SHOW function.
- Change illumination level or type
2224
%1 :\tSide on verification set not
measured
The defined side can not be
measured.
- Displacement too big
- Wrong measurement position - Check proper functioning of the verification set
2225
%1 :\tNot able to detect a bad
mark Not able to detect any bad mark. - Fiducial/Bad Mark camera not above bad mark.
- Move camera above bad mark.
- Modify light levels of bad mark description.
- Adapt action-spec. for bad mark location.
2226
%1 :\tComponent Mismatch
(sides)
Mismatch between the component
description and the measured
component characteristics.
Distance between the sides - Wrong component description used. - Verify component and component description by SHOW function.
2227
%1 :\tError reading vision package
(.CA, .FA, .BM)
The specified package is not
installed on the system. - Illegal modification on the system.
- Re-install vision images.
- Add specific vision image.
2228
%1 :\tLight calibration not
successfully completed Light calibration failed.
- Corner markers CA calibration plate are not clearly visible.
- Placement head positioning above CA camera not correct.
- Clean CA calibration plate (possibly also bottom side...).
- Check visibility and contrast of corner markers in image with lowered head.
2229 The nozzle is polluted or worn out
The nozzle is either polluted or
worn out.
- Clean the nozzle.
- Replace the nozzle.
2230
Component light-level teaching
failed
Component light-level teaching
failed.
- The component above the CA camera differs from the
specified component.
- Initial light level is not correct.
- Check component.
- Check initial light level of component.

2300 %1 :\tNot squared
The square EPDs on the Y2 axis
indicate a position difference of
more then 20 mm between the
axes Y1 and Y2.
- This error could be caused by another error (e.g. position
error Y1 or Y2).
- After initialization the offset data in HDV.CFG is not correct.
- Check for other related errors and solve them.
- Check offset data for Y1 and Y2 in HDV.CFG. This data should be refreshed
on every homing action.
2301
%1 :\tNo servo-power
No servo power available.
- Servo power off.
- Switch on servo power.
2302 %1 :\tQuickstop
A quickstop was activated due to
an unsafe situation on the
machine.
- One of the heads is not in a safe position during XY-
movement, due to a servo problem.
- One of the covers has been opened during movement of the
machine.
- Check servo-system of the head causing the emergency input active.
- Close the cover, and retry the action.
2303
%1 :\tLIMMS error
A (low) grade error is signalized.
See Service Manual.
See Service Manual.
2304 %1 :\tFatal LIMMS error
A serious error has been reported
by an axis. See Service Manual. See Service Manual.
2305
%1 :\tAlignment error
Error during magnetic alignment.
See Service Manual.
See Service Manual.
2306 %1 :\tHome-search error
The home position is not found.
This error is detected by LAPI.
- Communication failure between LAPI and axis.
- The error could be caused by a servo error (e.g. 'home-search
error 2336').
- Check for other errors and solve them.
- Retry operation.
- If problem still persists, contact your service representative.
2307 %1 :\tAxis connect error Unable to connect axis by CAN. - Malfunction of the CAN-bus network. - Check the CAN-bus network.
2308 %1 :\tI/O-Handler download error
I/O handler program in the Y2 axis
could not be downloaded.
- The I/O handler program as defined in HDV.CFG could not be
found.
- LAPI function 'LsdlohDownload' failed. - Contact your service representative.
2309 %1 :\tI/O-Handler activate error
I/O handler program in the Y2 axis
could not be started. - LAPI function 'LsdlohActivate' failed. - Contact your service representative.
2310 %1 :\tAxis initialization error Not able to initialize H-drive. - LAPI function 'SacInitialize' failed. - Contact your service representative.
2311 %1 :\tLAPI init Error initializing LAPI layer.
- Initialization file CALSTART.CFG was not found or is
erroreous. - Contact your service representative.
2312 %1 :\tNot all axes found
At startup of the aPC, during the
search over the CAN bus, not all
axes were found.
- CAN-address on the LAC is set to faulty.
- The range of network addresses to scan for is not correct.
- Defective LAC.
- Defective CAN-bus connection.
- Check CAN-addresses on the LAC.
- Check the range of network-adresses to scan for in CALSTART.CFG.
- Check CAN-bus connections.
2313 %1 :\tMeasurement alarm
The signal level of the
measurement system is too low.
- Filthiness of linear scale or measuring head.
- Alignment of measuring head to linear scale not correct.
- Clean linear scale and measuring head.
- Check alignment of measuring head to the linear scale.
- Retry action.

2314 %1 :\tOver-voltage error
An over-voltage on the 325 VDC
has been detected.
- The ballast resistor on the power supply unit has not been
switched on correctly, while an axis or more axes were
decelerating.
See service manual.
- Check the continuity and resistance (100 ohm) of the ballast resistor on
connector X4 on the power supply unit.
- If OK, the switching is faulty; replace power supply unit.
See Service Manual.
2315 %1 :\tAmplifier current overflow
Linear motor current was
measured as too high in one ot the
amplifier units.
- Short circuit in the motor.
- Defective wiring between amplifier and motor.
- Defective amplifier unit.
See Service manual.
- Check connections between amplifier and motor.
- Check resistance between motor coils: 8.8 ohm (+3/-1). If fault replace
carriage.
- Replace amplifier unit.
See Service manual.
2316 %1 :\tFatal position error
During the move the carriage has
reached a not correct position.
- This error can be caused by another error. See the
APC_EVT.LOG file.
- The error criterion is set too small.
- Mechanical friction of the axis is too high.
- Filthiness or malfunction of linear scale.
- Refer to APC_EVT.LOG file for other errors (e.g.
EM_HDV_NOT_SQUARED).
- Check HDV.CFG file; the error criterion must be 0.5 mm. and the
single/double sided configuration must be correct.
- Check friction current of the axis. If too high, check the bal
2317 %1 :\tSteady-state position error
After a move the carriage came to
a halt incorrectly.
- The error criterion is set too small.
- Mechanical friction of the axis is too high.
- Filthiness or malfunction of linear scale.
- Check HDV.CFG file; the error criterion must be 5 micrometers, and the
single/double sided configuration must be correct.
- Check friction current of the axis. If too high, check the ball guides. If faulty,
replace ball guides and guide rails.
- Check
2328 %1 :\tFeedback check error
The feedback (position) is not
correct. See Service Manual. See Service Manual.
2329 %1 :\tLMS position error
The LMS system report an internal
defect.
- Dirt or grease on the linear scale.
- Malfunction LMS cabling.
- Electro-magnetic disturbance on the wiring.
- Defective LMS system.
See Service Manual.
- Clean the linear scale and optical pickup; retry operating XY-system.
- Check output of LMS. If correct, check connections between LMS and LAC.
- Check for electro-magnetic disturbance.
- If connections OK, replace LMS.
See Service Manual.
2330 %1 :\tTemperature error
A too high temperature on the H-
drive is detected.
- Current application program requires too much acceleration or
deceleration from the carriage.
- Malfunction of sensor wiring.
- Malfunction of temperature sensor.
- Check sensor wiring.
- Check sensor.
- If OK, report error to your service representative.