7.1 Use a shielded twisted-pair cable. The shielding
must be connected to the chassis at both ends
and be earthed at one point.
7.2 Keep potential sources of disturbance at the rec-
ommended distance from the cable. Make sure
that the length of the cable does not exceed the
value specified in the product data sheet.
7.3 Ensure that the cable’s bending radius exceeds
the permitted minimum value.
7.4 Treat all wires as live. Any wires not in use must
be insulated.
7.5 Do not combine old encoder parts with new
ones, when replacing a worn out encoder.
7.6 If the product comes with an earthing strap, this
must be connected to the chassis of the machine.
7.1 Verwenden Sie ein geschirmtes, paarig verseiltes
Kabel. Der Schirm soll auf beiden Seiten aufge-
legt und an einer Stelle geerdet werden.
7.2 Potenzielle Störquellen auf empfohlenem Ab-
stand halten. Sicherstellen, dass die Kabellänge
nicht den im Produktdatenblatt angegebenen
Wert überschreitet.
7.3 Sicherstellen, dass der Biegeradius des Kabels
über dem zulässigen Mindestwert liegt.
7.4 Sämtliche Leiter als stromführend betrachten.
Nicht genutzte Leiter isolieren.
7.5 Beim Auswechseln von Drehgebern niemals
alte und neue Drehgeberkomponenten miteinan-
der kombinieren.
7.6 Wird das Produkt mit einem Erdungsband gelie-
fert, ist dieses an das Maschinengestell anzu-
schließen.
7.1 使用屏蔽双绞线电缆。屏蔽电缆必须连接到底
座两端,并单点接地。
7.2 请将潜在干扰源放置在离电缆建议的距离外。
确保电缆长度不超过产品数据表中的规定值。
7.3 确保电缆的弯曲半径超过所允许的最小值。
7.4 将所有导线视为带电线路。必须对所有未使用
的导线做绝缘处理。
7.5 更换坏的编码器时,请勿将新旧编码器部件相
互结合。
7.6 如果产品有接地带,必须将其连接到底座。
17
Leine Linde products conform to several standards
and approvals. Certificates and documentation may
be provided upon request to your local Leine Linde
representative.
8.1 UL/CSA standards, type approval
Most Leine Linde products have been type
tested in accordance with IEC 61010. The product
box label states if the product conforms to the
standard. When the product is to be operated
in accordance with IEC 61010-1, the power must
be supplied from an isolated secondary circuit
with current or energy or power limitation as
per IEC 61010-1, IEC 60950-1, or by a class 2
secondary circuit as specified in UL 1310.
8.2 CE marking and Declaration of conformity
Most Leine Linde products conform to the
protection requirements of Council Directive
2014/30/EU related to EMC when applicable.
The product box label states if the product
conforms to the standard.