User Manual SIPLAC E CF 2 Operational safety Software version SR.101.xx 06/2003 US Edition 2.5 Safety equipment 47 2.5.2 Guard on the input/output belt W ARNING The guard must a lways be se t to the hei ght of th e PCB t…

100%1 / 188
2 Operational safety User Manual SIPLACE CF
2.5 Safety equipment Software version SR.101.xx 06/2003 US Edition
46
2.5.1.1 General
The gantry positioning range is covered by two protective covers. If you want to open the protec-
tive covers, first press the Stop button (item 1 in Fig. 2.5 - 2
) or the emergency stop button (item
2 in Fig. 2.5 - 2
). The power to the gantry axes will be switched off and the gantries will stop
immediately. If you open one of the protective covers or a guard on the incoming or outgoing con-
veyor, the power to the gantry axes will be switched off. They will stop immediately.
If the key switch is closed (position I), you can continue to pace the star at reduced speed while
the protective covers are open.
Placement will stop if you press the emergency stop button. You can then either cancel or con-
tinue placement of the PCB. The protective covers at the sides can be opened in order to refill
with components when the machine has stopped.
WARNING
The protective covers must only be opened, with the key switch closed (position I), by appropri-
ately qualified and trained personnel. 2
Fig. 2.5 - 2 Stop and emergency stop buttons
(1) Stop button
(2) emergency stop button
(3) Key-operated switch
User Manual SIPLACE CF 2 Operational safety
Software version SR.101.xx 06/2003 US Edition 2.5 Safety equipment
47
2.5.2 Guard on the input/output belt
WARNING
The guard must always be set to the height of the PCB to be processed. Ensure that the gap
between the guard and the safety bar is as small as possible. 2
Guards are fitted on the input and output belts of the PCB conveyor.
The height of the guard must be set using the slots so that the processed PCB can travel
through.
2
Fig. 2.5 - 3 Guard on the placement machine
(1) Safety bar (fixed)
(2) Guard (adjustable)
(3) Slots for adjusting the height
(4) Cover
2 Operational safety User Manual SIPLACE CF
2.5 Safety equipment Software version SR.101.xx 06/2003 US Edition
48
2.5.3 Emergency stop buttons, protective cover switches ...
2
Fig. 2.5 - 4 Location of the buttons and protective contactor combinations K1, K2
2
(1) Stop button
(2) Start button
(3) Emergency stop button
(4) Emergency stop button
(5) Start button
(6) Stop button
(7) Component counter
(8) Key switch open:position 0 for normal mode
Key switch closed: position I for service purposes
(9) Protective cover switch (output conveyor, 00303617-xx)
(10) Protective cover switch (right, 00321417-xx)
(11) Protective cover switch (input conveyor, 00303614-xx)
(12) Protective cover switch (left, 00321416-xx)