Specification SIPLACE X-Series S 规格说明书.pdf - 第11页

11 Modular machine concept Example of SIPLACE X4i S NC NC C&P20 P2 C&P20 P2 NC NC PA1 PA2 C&P20 P2 COT In C&P20 P2 PA1 Placement area 1 PA2 Placement area 2 OP Operator panel C&P20 P2 SIPLACE SpeedSta…

100%1 / 68
10
Modular machine concept
Example of SIPLACE X4 S
NC
NC
CPP
CPP
NC
NC
PA1
PA2
CPP
COT
CPP
PA1 Placement area 1
PA2 Placement area 2
OP Operator panel
CPP SIPLACE MultiStar
NC Nozzle changer
NC2 Nozzle changer "row 2"
CAM Stationary cameras
BZ Buffer zone
COT Changeover table
IN Input area - conveyor
OUT Output area - conveyor
OP
OP
BZ
PLEASE NOTE: For all possible head configurations please refer to section Machine performance from page 12.
COT
COT
COT
IN
OUT
OUT
BZ
IN
CAMCAM
NC2
NC2
11
Modular machine concept
Example of SIPLACE X4i S
NC
NC
C&P20 P2
C&P20 P2
NC
NC
PA1
PA2
C&P20 P2
COT In
C&P20 P2
PA1 Placement area 1
PA2 Placement area 2
OP Operator panel
C&P20 P2 SIPLACE SpeedStar
NC Nozzle changer
BZ Buffer zone
COT In Changeover table at the inner
position
IN Input area - conveyor
OUT Output area - conveyor
OP
OP
BZ
PLEASE NOTE: For all possible head configurations please refer to section Machine performance from page 12.
COT In
COT In
COT In
IN
OUT
OUT
BZ
IN
12
Machine performance
Placement head types SIPLACE SpeedStar (C&P20 P2)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
Placement performance
The placement performance is influenced by the different head combinations and head positions, plus the conveyor
configurations. Individual options and customized applications also influence the placement performance. On
request, ASM can calculate the actual performance of your product on your machine configuration.
IPC value [components/h]
According to the vendor-neutral conditions of the IPC 9850 standard published by the Association of Connecting
Electronics Industries.
SIPLACE benchmark value [components/h]
The SIPLACE benchmark value is measured during the machine acceptance tests. It corresponds to the conditions
set out in the ASM scope of service and supply.
SIPLACE X2 S
See the note above for definition of placement performance values.
Machine Placement area 1 Placement area 2 IPC value Benchmark
value
X2 S-A C&P20 P2 C&P20 P2 65,000 75,000
C&P20 P2 CPP_L 51,200 59,500
C&P20 P2 CPP_H 49,250 57,000
CPP_L CPP_L 37,400 44,000
CPP_H CPP_H 33,500 39,000
CPP_L CPP_H 35,450 41,500
X2 S-B C&P20 P2 TH 37,000 42,500
CPP_L TH 23,200 27,000
CPP_H TH 21,250 24,500
X2 S-C TH TH 9,000 10,000
SIPLACE X3 S
See the note above for definition of placement performance values.
Machine Placement area 1 Placement area 2 IPC value Benchmark
value
X3 S-A C&P20 P2 / C&P20 P2 C&P20 P2 97,500 112,500
C&P20 P2 / C&P20 P2 CPP_L 83,700 97,000
C&P20 P2 / C&P20 P2 CPP_H 81,750 94,500
CPP_L/CPP_L CPP_L 57,375 67,500
CPP_H / CPP_H CPP_H 50,250 58,500
CPP_L/CPP_L CPP_H 54,150 63,500
X3 S-B C&P20 P2 / C&P20 P2 TH 69,500 80,000
CPP_L/CPP_L TH 41,900 49,000
CPP_H / CPP_H TH 38,000 44,000
X3 S-C CPP_H/TH TH 25,750 29,500
X3 S-D TH / TH TH 12,500 14,000
CPP_H = Multistar CPP in high assembly position
CPP_L = Multistar CPP in low assembly position