Specification SIPLACE X-Series S 规格说明书.pdf - 第30页
30 Component feeding Alternative SIPLACE modules SIPLACE MeasuringFeeder X Description The SIPLACE MeasuringFeeder X is used to prevent placement of incorrect components by ver- ifying the electrical values of configured…

29
Component feeding
Alternative SIPLACE modules
SIPLACE Glue Feeder
The SIPLACE Glue Feeder
allows you to position dots of
adhesive on a component,
before it is placed. These
dots of adhesive can then be
checked by the SIPLACE
Vision system. The required
glue dots can be defined in
the Component Shape Editor
in SIPLACE Pro and you can
also define whether individ-
ual dots of adhesive are to be
excluded from inspection or
not.
This adhesive function can
be enabled and disabled in
the Component Editor in
SIPLACE Pro. The SIPLACE
Glue Feeder is a special
feeder module which needs
to be configured as a fixed
feature on a certain table
track. It occupies 5 locations
of an 8 mm X feeder module,
max. 1 per head.
SIPLACE LDU 2 X
The SIPLACE LDU 2 X is
used for coating flip chips
and CSP components with
flux. The flux container slides
with a linear movement over
the dip plate and coats the
cavity in the dip plate with a
layer of flux (predefined layer
thickness). The parameters
for coating a component with
flux are prescribed in
SIPLACE Pro.
The component is coated
and then the flux layer is
renewed.
This sequence guarantees
consistent processing condi-
tions for the components.
The SIPLACE LDU 2 X is
taken into account as an
independent feeder module
type in the setup. An imple-
mented warming function
allows the viscosity of the
flux to be altered. It occupies
9 locations of an 8 mm X
feeder module.
SIPLACE
PowerConnector X
The SIPLACE
PowerConnector X helps to
resolve problems connected
to SIPLACE X feeder mod-
ules in the machine, without
the need to stop the produc-
tion process.

30
Component feeding
Alternative SIPLACE modules
SIPLACE MeasuringFeeder X
Description
The SIPLACE
MeasuringFeeder X is used
to prevent placement of
incorrect components by ver-
ifying the electrical values of
configured components. This
supports identification of
setup errors, such as mixed
up component tapes, incor-
rectly labeled component
reels or reels with counter-
feit, non-functional compo-
nents.
The SIPLACE
MeasuringFeeder X does
not feed in components itself
but instead measures com-
ponents which are already
on the changeover table, in
conventional tape feeder
modules. All components for
which an electrical value has
been stored in SIPLACE Pro
are picked up by the place-
ment head and the relevant
values are determined via
two contacts in SIPLACE
MeasuringFeeder X.
The SIPLACE
MeasuringFeeder X can
measure capacitors, resis-
tors and inductors, plus
diodes.
It can measure two-pin com-
ponents, which have contact
surfaces on the underside of
the component and a size of
at least (L x W)
0.6mmx0.3mm to
6 mm x 3.2 mm. It deter-
mines the capacity of capac-
itors, the electrical resistance
of resistors and the inductiv-
ity of inductors. It also checks
the blocking direction of
diodes and thereby the polar-
ity.
Measurable value range of components:
Component type Measuring range Measuring tolerance
Capacitors 1 pF - 100µF (standard)
100 nF - 500µF (polarized)
± 5%
Resistors 100 mOhm- 1MOhm ± 5%
Diodes Forward voltage 0.2 - 4 V Polarity check
Inductors 1µH - 1mH ± 15%
SIPLACE MeasuringFeeder X
Contact module

31
Component feeding
Tray holders
Technical data for waffle pack tray SIPLACE X
Dimensions LxWxH 429 x 376 x 200 mm³
Locations occupied on the
SIPLACE X component trolley
32
Positioning options on X-Series S
placement machines
Locations 2 and/or 4
Placement head range TwinStar, MultiStar
Max. waffle pack tray height
including components
MultiStar
TwinStar
16 mm
30 mm
Tray holder SIPLACE X