i3070-Software-Installation.pdf.pdf - 第5页

i3070 Software Installation 5 System requirements Befor e installing the softwar e, ensur e tha t the workstation has a DVD-ROM drive and meets the following specifications. T able 1 System r e quirements Specifications …

100%1 / 24
4 i3070 Software Installation
Preparation
1 Ensure that the PC meets the System requirements on page 5.
2 Make a complete system backup before installing the software.
3 If you are upgrading the i3070 software from a previous release:
a At least back up the critical files listed in Table 2, if you are unable to do a
full backup.
b Remove the previous releases of the i3070 software using the Remove All
option. See Uninstalling the i3070 In-Circuit Test Software on page 22.
4 Redeem your software licenses following the instructions in your Software
Entitlement Certificate.
Then proceed to Installing the i3070 Software on page 7.
i3070 Software Installation 5
System requirements
Before installing the software, ensure that the workstation has a DVD-ROM drive
and meets the following specifications.
Table 1 System requirements
Specifications
Processor Recommended: Intel Core i5 (4th Generation or newer) or equivalent
Operating System Windows 10 Pro (64-bit)
Windows 10 Enterprise (64-bit) version 1903 or later
Windows 11 Pro
Ensure that all Windows updates are installed.
Memory Recommended: 8 GB of RAM (minimum 4 GB)
Available Disk Space Recommended: 10 GB (minimum 5 GB), must be on drive C
Display Properties Screen resolution: at least 1280 x 1024 pixels
Color quality: at least 16-bit
Language Setting Must be English (United States).
If you are upgrading a controller to Windows 10, ensure that
it meets the Windows system requirements and there are no
compatibility issues.
6 i3070 Software Installation
Critical folders and files
If you are upgrading a system, you can use the following shell command to capture
most of the computer’s networking information:
ipconfig /all > mynetwork.txt
This saves the networking data to mynetwork.txt, which you can refer to when
restoring the network settings.
Back up the critical files if you are unable to make a complete system backup.
1. These files are not on a test development workstation.
2. The default installation folder may be I3070_ICT or Agilent_ICT.
Table 2 Critical folders and files
Folders/files Description
\windows\system32\drivers\etc\hosts Local hostname resolution and networking information
\windows\system32\drivers\etc\bootptab Hardware addresses for the testhead
1
\<installation folder>\autofile Fixtures ID auto numbers
\<installation folder>\boards Board test programs. If your board files are in a different folder,
back up that folder.
\<installation folder>\diagnostics\th1\ASRU_Reference System Calibration file (system dependent)
\<installation folder>\diagnostics\th1\config Testhead hardware configuration
1
\<installation folder>\home User’s home folder
\<installation folder>\standard\config Testhead resources configuration
1
\<installation folder>\dev Back up any ps (DUT power supply) files that were customized.
Any other custom folders and files containing important
data.
Any other user data