Installation Manual SIPLACE Setup Center 2.2 5.2.3.3.2 Setting the CAN Bus Address You need to set a CAN Bus addre ss for each docking station. This CAN Bus address must be different for each docking station. 5 Set the…

SIPLACE Setup Center 2.2 Installation Manual
Click on Finish to finish the installation.
5.2.3.3 Installing Docking Station
5.2.3.3.1 Safety Instructions
26 of 90

Installation Manual SIPLACE Setup Center 2.2
5.2.3.3.2 Setting the CAN Bus Address
You need to set a CAN Bus address for each docking station. This CAN Bus address must be
different for each docking station. 5
Set the CAN Bus address for the docking station.
5
Make sure that you only assign each address once, when setting the CAN Bus address,..
5.2.3.3.3 Establishing a Data Connection
Establish a data connection between the docking station and the SC PC. This data connection is
realized via a CAN Bus. You have already installed the CAN card in your PC, see Section
“Installing the CAN Card in the PC” on page
20. 5
Connect the CAN cable to the docking station and the PC. This CAN cable has 5 connections,
one of which you can use for the PC. This leaves 4 other connections, allowing you to connect up
to 4 docking station with this cable. 5
Connect the CAN cable to the CAN connection at your docking station. This can be found
on the back of the docking station.
Connect the CAN cable to the CAN card on the PC (CAN Bus 1 or 2).
27 of 90
-

SIPLACE Setup Center 2.2 Installation Manual
See the chapter
8.1 CAN Bus Cable Connection Examples for connection scenarios.
5.2.3.3.4 Compressed Air and Power Supplies
Connect to the compressed air supply.
Set the pressure reducer on the pneumatic connection (external) to 5.5 bar.
Switch off the power supply and connect the CAN Bus cable to the device.
Switch on the power supply.