00197623-03_VD_708.1_SP2_DE_EN.pdf - 第29页
Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 29 F ault - tolerant operation of the T win Head – If Segment 1 has b een deactivated or removed from t he configurat ion, e.g. some single place…
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
28
Counter for operating hours
– If the placement machine is switched off abruptly or by a direct "shutdown" of the station
software console, the current value does not get stored in the EPROM on the I/O module. In
such cases the difference to the latest storage time gets lost (maximum 5 minutes deviation).
– The counter for operating hours gets lost if two or more of the components I/O module, GCU or
station computer are exchanged.
Automatic recognition of the nozzle ID
– Twin heads and SOKO nozzles of the C&P heads are not supported.
– The scanned nozzle data gets lost at a machine reboot.
Flexible management of activity level rights
– No message is displayed that a new activity level is active.
– The rights can solely be changed via mouse / trackball (right-click). A change via touchscreen
is not possible.
X4i S placement machine
– The traveling range in X direction is limited for the gantries 2 and 4 on the X4Si placement
machine.
TrayStack Feeder AX
– The feeder is only supported on the X4i S placement machine and can be positioned on the
locations 2 and 3 only.
– Only one Dip module LDU-X can be installed beside the feeder.
– If 2 TrayStack Feeder AX are installed together with an LDU-X, the table has to be manually
selected in the Auto Configuration.
– No nozzle changer support.
– Stationary camera cannot be used.
– CPP placement head supported only.
– Feeder and placement heads are neither controlled in SIPLACE Pro nor in the station software.
– Due to the hardware, the sequence oft he components (chain) cannot be warranted. Therefore,
setup verification with SIPLACE Setup Center cannot be performed.
– After the machine has been rebooted or the feeder has been locked / unlocked, the feeder has
to be manually activated with the buttons on the feeder each time.
– If the feeder is used without a reject conveyor, this may result in incomplete head cycles what
causes a reduced placement performance.
– If there is no space to put back the component, it will be rejected.
Fine adjustment of the pitch at the feeder
For feeder types < 12mm, the current pitch in the feeder has to be set to > 4mm to achieve the
same functionality as on the operator panel of the feeder and to avoid incorrect settings for smaller
pitches.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
29
Fault-tolerant operation of the Twin Head
– If Segment 1 has been deactivated or removed from the configuration, e.g. some single
placement positions might not be reachable because of the limited traveling range of Segment
2. The machine stops with a corresponding error message and the board cannot be finished.
No plausibility check will be performed in advance for a defined job or a board that enters the
machine.
– Head calibration is not possible, if Segment 1 is deactivated or has been removed from the
configuration. If this is necessary, the functioning segment has to be installed on the position of
Segment 1.
– No CAN communication with a segment that has been removed from the configuration.
– No control of the Z-security for a segment that has been removed from the configuration.
– A segment that has been removed from the configuration will not be actively secured, but will
generally be hold by the cylinder.The segment is held high enough, so that it will not come in
touch with placed components. If necessary, the nozzle has to be manually removed.
– If a long/wide component is placed by the active segment, no check will be performed whether
a component is wiped off from the segment that has been removed from the configuration.
PCB barcode detection with Molex Traceability Pad
– Barcode-controlled production is not supported.
– Traceability is not possible until the barcode has been successfully read. Therefore, the
Traceability Pad should be placed / read in placement area 1 of the first placement machine in
the line. Only in this case, it is warranted that the Traceability information can be correctly
saved for all stations in the line.
– No plausibility check if the placement position is to close to a component.
– Barcodes can only be reliably measured by SIPLACE Vision if the component height (without
board warpage) at the position of the Traceability-Pad is < 1,5mm.
– When the placement position is taught, the barcode / fiducial position will not be moved
correspondingly.
C&P20 M placement head
Supported on the CA-series and SIPLACE X4 S micron / X4i S micron placement machines only.
C&P20 P placement head
Supported on the X-series S placement machines only.
Twin VHF placement head
– Supported on the SX1/SX2 V2 placement machine (with a higher positioned gantry) only.
– No fast gantry exchange possible.
– Must not be used together with the VHF P&P placement head on a machine.
SIPLACE JTF-S
Supported on the SX1/SX2 V2 and SIPLACE X-series S placement machines only.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
30
SIPLACE JTF-M
– Supported on the SX1/SX2 V2, X4i S micron and SIPLACE X-series S placement machines
only.
– On the SX1/SX2 V2 placement machine no tape feeder can be placed on the location beside
the JTF-M because no empty tape channel is available.
SIPLACE Wafer Systems
– Supported on the CA-series placement machines only.
– A specific table is required.
External virtual ink spot handling
– Only possible for stations with station software from version 707.0 and SIPLACE Pro from
version 11.1.
– Physical and virtual ink spots must not be mixed.
– The board must not contain any active ink spots.
Software installation on older placement machines
During the station software installation on older X-series or X S-series placement machines that are
equipped with a CPP placement head and an MTC at location 2, a message is displayed that the
travel range has to be remeasured.
This occurs once to initialize the buffer monitoring. Thereafter, it will be checked if a retrofit has
been performed that requires a recalibration of the travel range.
CPP / Twin Head placement heads on SIPLACE CA series
– Stationary cameras may be installed on location 1 and 3 only.
– Twin Head may be installed on location 3 only.
– The CPP placement head is only supported in the high position on SIPLACE Wafer Systems.
Measuring and changing the component height measured by the component sensor at the
station
– Only for placement heads that are equipped with a component sensor.
– Only for nozzle and component combinations in which the component height is supposed to be
measured with the component sensor.
– The component sensor will not perform any measurement if the component height
measurement is omitted due to SIPLACE Pro rules.
Conveyor Carrier X
– No travel range check.
– No pickup simulation.
– The Conveyor Carrier X uses one track on an X-table virtually. If the real table should be
completely occupied, the operator might have to remove a feeder from the table to create place
for the virtual feeder.
– No I-Placement mode.
– The SIPLACE Pro Optimizer does not consider the time it takes to fill up a tray with
components and change it.