Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
30
SIPLACE JTF-M
Supported on the SX1/SX2 V2, X4i S micron and SIPLACE X-series S placement machines
only.
On the SX1/SX2 V2 placement machine no tape feeder can be placed on the location beside
the JTF-M because no empty tape channel is available.
SIPLACE Wafer Systems
Supported on the CA-series placement machines only.
A specific table is required.
External virtual ink spot handling
Only possible for stations with station software from version 707.0 and SIPLACE Pro from
version 11.1.
Physical and virtual ink spots must not be mixed.
The board must not contain any active ink spots.
Software installation on older placement machines
During the station software installation on older X-series or X S-series placement machines that are
equipped with a CPP placement head and an MTC at location 2, a message is displayed that the
travel range has to be remeasured.
This occurs once to initialize the buffer monitoring. Thereafter, it will be checked if a retrofit has
been performed that requires a recalibration of the travel range.
CPP / Twin Head placement heads on SIPLACE CA series
Stationary cameras may be installed on location 1 and 3 only.
Twin Head may be installed on location 3 only.
The CPP placement head is only supported in the high position on SIPLACE Wafer Systems.
Measuring and changing the component height measured by the component sensor at the
station
Only for placement heads that are equipped with a component sensor.
Only for nozzle and component combinations in which the component height is supposed to be
measured with the component sensor.
The component sensor will not perform any measurement if the component height
measurement is omitted due to SIPLACE Pro rules.
Conveyor Carrier X
No travel range check.
No pickup simulation.
The Conveyor Carrier X uses one track on an X-table virtually. If the real table should be
completely occupied, the operator might have to remove a feeder from the table to create place
for the virtual feeder.
No I-Placement mode.
The SIPLACE Pro Optimizer does not consider the time it takes to fill up a tray with
components and change it.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
31
Individual barcode fiducials
Barcode fiducials in trays are not supported.
Barcode fiducials on the component underside are not supported because in this case the
barcode is read before the component is picked up.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
32
9 Corrected Errors
708.1 SP2 Station Software
The 708.1 SP2 station software version contains all error corrections of the previous 701.xx
708.1 SP1 versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-114620601 The CAN card was not recognized during the first machine configuration.
D1-114934101 The production could not be started when a connected MTC was switched off.
D1-116350301 Sporadically LED components were placed separately and this reduced the
performance of the machine.
D1-116638601 Changes within the parameter settings for the Glue Feeder were not
transferred to the feeder.
D1-116695601 Sporadically, a nozzle could neither be put back into the magazine nor
rejected.
D1-114908602 A dirty or defective pressure regulation valve was not detected.
D17753-22701 Conveyor parameter Current at lifting table was not calculated correctly.
708.1 SP1 HF2
D1-114615401 During production the station software interface was suddenly no longer
responding. After restart it was ok.
D1-116251101 Feeder error messages were no longer included in the "EventLog" file.
708.1 SP1 HF1
D1-114500709 The C&P20 P component sensor calibration was not successful.
D1-114651365 eSW: The board could not be transported with the Advanced PCB Interface.
D1-114925901 The occupancy check for the MTC did not report any error message in case of
a faulty occupancy.
D1-115713001
D1-115727701
D1-115788501
The CPP component censor calibration was not successful; the height
reference run of the 2
nd
segment broke.
D1-115729601
D1-115739301
The temperature compensation could not be started although the temperature
was shown and the sensor running.
D1-115758001 eSW: The PCB barcode reader could not be configured.