00197623-03_VD_708.1_SP2_DE_EN.pdf - 第30页

Station Software 7 08.1 SP2 / Version Description Ausgabe 10/2015 E dition 30 SIPLACE JTF -M – S upported on the S X1/SX2 V2 , X4i S micron and SIPLACE X - series S placement machines only . – On the SX1/SX2 V 2 placemen…

100%1 / 92
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
29
Fault-tolerant operation of the Twin Head
If Segment 1 has been deactivated or removed from the configuration, e.g. some single
placement positions might not be reachable because of the limited traveling range of Segment
2. The machine stops with a corresponding error message and the board cannot be finished.
No plausibility check will be performed in advance for a defined job or a board that enters the
machine.
Head calibration is not possible, if Segment 1 is deactivated or has been removed from the
configuration. If this is necessary, the functioning segment has to be installed on the position of
Segment 1.
No CAN communication with a segment that has been removed from the configuration.
No control of the Z-security for a segment that has been removed from the configuration.
A segment that has been removed from the configuration will not be actively secured, but will
generally be hold by the cylinder.The segment is held high enough, so that it will not come in
touch with placed components. If necessary, the nozzle has to be manually removed.
If a long/wide component is placed by the active segment, no check will be performed whether
a component is wiped off from the segment that has been removed from the configuration.
PCB barcode detection with Molex Traceability Pad
Barcode-controlled production is not supported.
Traceability is not possible until the barcode has been successfully read. Therefore, the
Traceability Pad should be placed / read in placement area 1 of the first placement machine in
the line. Only in this case, it is warranted that the Traceability information can be correctly
saved for all stations in the line.
No plausibility check if the placement position is to close to a component.
Barcodes can only be reliably measured by SIPLACE Vision if the component height (without
board warpage) at the position of the Traceability-Pad is < 1,5mm.
When the placement position is taught, the barcode / fiducial position will not be moved
correspondingly.
C&P20 M placement head
Supported on the CA-series and SIPLACE X4 S micron / X4i S micron placement machines only.
C&P20 P placement head
Supported on the X-series S placement machines only.
Twin VHF placement head
Supported on the SX1/SX2 V2 placement machine (with a higher positioned gantry) only.
No fast gantry exchange possible.
Must not be used together with the VHF P&P placement head on a machine.
SIPLACE JTF-S
Supported on the SX1/SX2 V2 and SIPLACE X-series S placement machines only.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
30
SIPLACE JTF-M
Supported on the SX1/SX2 V2, X4i S micron and SIPLACE X-series S placement machines
only.
On the SX1/SX2 V2 placement machine no tape feeder can be placed on the location beside
the JTF-M because no empty tape channel is available.
SIPLACE Wafer Systems
Supported on the CA-series placement machines only.
A specific table is required.
External virtual ink spot handling
Only possible for stations with station software from version 707.0 and SIPLACE Pro from
version 11.1.
Physical and virtual ink spots must not be mixed.
The board must not contain any active ink spots.
Software installation on older placement machines
During the station software installation on older X-series or X S-series placement machines that are
equipped with a CPP placement head and an MTC at location 2, a message is displayed that the
travel range has to be remeasured.
This occurs once to initialize the buffer monitoring. Thereafter, it will be checked if a retrofit has
been performed that requires a recalibration of the travel range.
CPP / Twin Head placement heads on SIPLACE CA series
Stationary cameras may be installed on location 1 and 3 only.
Twin Head may be installed on location 3 only.
The CPP placement head is only supported in the high position on SIPLACE Wafer Systems.
Measuring and changing the component height measured by the component sensor at the
station
Only for placement heads that are equipped with a component sensor.
Only for nozzle and component combinations in which the component height is supposed to be
measured with the component sensor.
The component sensor will not perform any measurement if the component height
measurement is omitted due to SIPLACE Pro rules.
Conveyor Carrier X
No travel range check.
No pickup simulation.
The Conveyor Carrier X uses one track on an X-table virtually. If the real table should be
completely occupied, the operator might have to remove a feeder from the table to create place
for the virtual feeder.
No I-Placement mode.
The SIPLACE Pro Optimizer does not consider the time it takes to fill up a tray with
components and change it.
Station Software 708.1 SP2 / Version Description Ausgabe 10/2015 Edition
31
Individual barcode fiducials
Barcode fiducials in trays are not supported.
Barcode fiducials on the component underside are not supported because in this case the
barcode is read before the component is picked up.