00195642-01_IM-SetupCenter-3.0_EN.pdf - 第63页

Installation Setup Center Software Installation Installation Manual SIPLACE Setup Center V3.0 63 X Click Next to continue. Setup 5b Fill Level Control (2) X If the filling level correction should be allow ed, activate th…

100%1 / 94
Installation
Software Installation Setup Center
62 Installation Manual SIPLACE Setup Center V3.0
X Click Next to continue.
Step 4 Configuration of the Splice detection
X Select the checkbox Splice detection existing, if a splice detection is available.
X Enter the COM Port where Splice detection is plugged in or leave empty the entry field.
X Click Next to continue.
Step 5a Fill Level Control (1)
X If the fill level control should be disabled for single tracks, activate the checkbox “Running tracks”
empty is permitted. After that you can let single tracks go empty consciously.
NOTE:
This dialog will not appear for X-serie machines since the splice interface is always integrated
into the X feeders and is not available for S feeders at these machines!
Installation
Setup Center Software Installation
Installation Manual SIPLACE Setup Center V3.0
63
X Click Next to continue.
Setup 5b Fill Level Control (2)
X If the filling level correction should be allowed, activate the checkbox Operator may correct the
filling level. After that the operator may correct the filling level. Otherwise only the user with the right
"LineEngineer" and higher can correct the filling level.
X Click Next to continue.
Step 6 Activation of locked tracks
X Choose Activation without barcode reading is allowed, you can activate the locked tracks on the
machine GUI, by clicking on the button chosen track in the overview of the empty feeders.
X If the checkbox is not selected, you can activate the locked tracks only by scanning the barcode of
packaging unit again.
Installation
Software Installation Setup Center
64 Installation Manual SIPLACE Setup Center V3.0
X Click Next to continue.
Step 7 Traceability
X Here you can choose whether the Traceability Data should be created.
X Furthermore you can select the File version 1.0 for standard TRC file or the File version 2.0 for
extended TRC file.
X Click Next to continue. Wait until the next dialog box appears. It can be take a few minutes.
Step 8 Overview of the settings
X Here you will see the overview of the settings.
X Click Back to review or change the settings.
X Click Next to continue the installation.
NOTE:
Traceability settings can only be changed, if the Traceability Option is installed at the station.