1-8 Tg1576-ID-SO 0709-003 2.3 Outline for the Installation 2.3 Outline for the Installation Remove the feeder package replacement cart from the GXH main machine and set the single-transfer tray feeder on the feeder base.…

1-7
Tg1576-ID-SO
0708-002
2.2 Outline of Actions
2.2 Outline of Actions
(1) Set a new tray on the xed pallet and close the tray supply door.
(2) Press the [TRAY READY] button.
Pressing the [TRAY READY] button locks the tray supply door and
transfers the pallet to the component pick-up position.
(Pallet transfer cylinder forward limit)
(3
) The placement head on the GXH series main machine will pick up the
components from the pallet located on the component pick-up position
according to the pattern program.
(4) The images of the picked components (the componen
ts picked up by
the placement heads) are captured and recognized by the component
recognition cameras to detect the deviation in the pickup position.
The detected deviation is corrected and the components are placed
accurately on the specied positions.
When a pickup error or a recognition error is detected during the
component recognition, the machine performs the discharge operation
of the rejected component.
(5) Repeat Steps (
3) and (4).
When the component on the pallet runs out, the head stops the pick-
up operation and the tower light warns the component shortage to the
operator.
When the pallet is returned to the tray supply position (Pallet transfer
cylinder backward limit), open the tray supply door and change the tray.

1-8
Tg1576-ID-SO
0709-003
2.3 Outline for the Installation
2.3 Outline for the Installation
Remove the feeder package replacement cart from the GXH main machine
and set the single-transfer tray feeder on the feeder base.
When the single-transfer trays are to be installed, the feeder connector
connection Nos. are as follows:
•
Stage 1 :
103 (105 and 107 connectors are used simultaneously)
•
Stage 2 : 213 (215 and 217 connectors are used simultaneously)
•
Stage 3 : 313 (315 and 317 connectors are used simultaneously)
•
Stage 4 : 403 (405 and 407 connectors are used simultaneously)
Max. 5 tape feeders can be set on the feeder base where the single-transfer
tray has been installed.
The tape feeder settable lanes are as follows:
•
Stage 1 :
141 to 150
•
Stage 2 : 201 to 210
•
Stage 3 : 301 to 310
•
Stage 4 : 441 to 450
CAUTION
If you insert your nger or hand into the gap between the main
machine and the cart, created when the cart is installed, you
might get injured due to the movable part.
Take the greatest care not to insert your hand or nger into the
machine while you operate the main machine.
If you insert your nger or hand into the opening left while the
tape feeder has not been installed, you might get injured due to
the movable part.
Take the greatest care not to insert your hand or nger into the
machine while you operate the main machine.
When the tape feeder is replenished, take care not to hit your
head on the single-transfer tray feeder, which might injure your
head.

1-9
Tg1576-ID-SO
3. Handling of Single-transfer Tray Feeder
Notice
Before installing a single-transfer tray feeder on the bank feeder
change cart, note the following.
· Lock the caster brakes (2 places) of the bank feeder change cart.
· If the
single-transfer tray feeder is seated aoat, vacuum
nozzles or the machine (GXH series) will be damaged, causing
pickup errors.
Be sure to install the single-transfer tray feeder correctly.
CAUTION
·
Be sure to hold the handle to move the bank feeder change cart.
·
While attaching the handle slides, be sure to prevent your
ngers from getting jammed.
·
Be careful not to hit your foot against the cart while moving the
bank feeder change cart.
·
Try to wear a pair of shoes that can protect your toes and have
slip- and puncture-resistance soles (thickness: 10 mm or more)
while working.