00193826-01.pdf - 第144页
6 Component handling User Manual SIPLACE CS 6.4 Component trolley Software version SR. 101.xx06/2003 US Edition 144 6.4.2 T ape cont ainer Reels up to 19" in diamete r may be used. Ins ert them into the div iding pl…

User Manual SIPLACE CS 6 Component handling
Software version SR.101.xx 06/2003 US Edition 6.4 Component trolley
143
6.4 Component trolley
6.4.1 Structure
The component trolley consists essentially of a chassis, a component feeder table on which the
feeder is mounted, a communication unit, a tape container and a waste container. Docking the
component trolley in or out is described in Section 5.9
, page 122 onwards.
Fig. 6.4 - 1 Component trolley
(1) Component trolley
(2) Communication unit
(3) Control button for raising the component feeder table
(4) Component feeder table
(5) Handle for locking and lowering the component feeder table
(6) Tape container
(7) Waste tape container
NOTE ON OPERATIONAL SAFETY
All component trolleys must be docked on the machine in order to operate it. If they are not, the
machine stays in EMERGENCY STOP status. The placement process is interrupted.

6 Component handling User Manual SIPLACE CS
6.4 Component trolley Software version SR.101.xx06/2003 US Edition
144
6.4.2 Tape container
Reels up to 19" in diameter may be used. Insert them into the dividing plates as shown in Fig. 6.5
- 2.
PLEASE NOTE 6
We recommend that you use spindles if the tape reel diameter exceeds 7". This will ensure that
the feeders operate reliably. 6
Fig. 6.4 - 2 Component trolley with tape container
(1) Component trolley
(2) Spindles
(3) Dividing plate
(4) Tape container
6.4.3 Compressed air supply for bulk case feeder
Bulkcase feeders require compressed air to operate. We therefore offer a compressed air supply
for bulkcase feeders as an optional extra.

User Manual SIPLACE CS 6 Component handling
Software version SR.101.xx 06/2003 US Edition 6.4 Component trolley
145
It is easy to fit. Use three screws DIN 912, M8x20 (item 3) to fix the compressed air supply (item 2)
to the component feeder table (item 1). The compressed air supply has retaining clips (item 4) on
the back. These secure the bulk case feeder to the component trolley and ensure that the com-
pressed air supply is working properly.
6
Fig. 6.4 - 3 Compressed air supply for bulk case feeders
(1) Component feeder table
(2) Compressed air supply for bulk case feeders
(3) Screw DIN 912, M8x20
(4) Retaining clamp