00193826-01.pdf - 第70页
3 Technical data User Manual SIPLACE CS 3.5 Dimensions and weight of the placement system Software version SR.101.xx06/2003 US Edition 70 3.5 Dim ensions and weight of the placement system 3.5.1 Dimensi ons of the place …

User Manual SIPLACE CS 3 Technical data
Software version SR.101.xx 06/2003 US Edition 3.4 Technical data – ratings
69
3.4 Technical data – ratings
3.4.1 Technical data – electrical ratings
3
3.4.2 Technical data – compressed air supply
3
3.4.3 Technical data – compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1)
3.4.4 Technical data – noise emissions
3
3.4.5 Technical data – permissible ambient factors
3
Supply voltage 3 x 400 VAC ± 5 %; 50/60 Hz (Europe)
3 x 208 VAC ± 5 %; 50/60 Hz (U.S.A.)
3 x 200 VAC ± 5 %; 50/60 Hz (Japan)
Fuses 3 x 16 A (3 x 400 VAC, 3 x 208 VAC, 3 x 200 VAC)
Total connected load 5 kVA
Total power 2 kW
Power failure Max. 20 msec
Compressed air pressure Min. 0.55 MPa (5.5 bar) to 1.0 MPa (10 bar), ½"-connection
Compressed air consumption 400 Nl/min.
Operating pressure Set to 0.52 MPa (5.2 bar)
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint +3°
Max. noise emission 74dB(A)
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 to 80%
(but no higher than 45% on average in order to prevent any
possibility of condensation on the machine).

3 Technical data User Manual SIPLACE CS
3.5 Dimensions and weight of the placement system Software version SR.101.xx06/2003 US Edition
70
3.5 Dimensions and weight of the placement system
3.5.1 Dimensions of the placement system
3
Fig. 3.5 - 1 Dimensions of the placement system in millimeters

User Manual SIPLACE CS 3 Technical data
Software version SR.101.xx 06/2003 US Edition 3.5 Dimensions and weight of the placement system
71
3.5.2 The placement system’s center of gravity
3
Fig. 3.5 - 2 The placement system’s center of gravity
X coordinate - 80 mm
Y coordinate 0 mm
Z coordinate 350 mm high
T PCB transport direction
These center of gravity coordinates relate to placement systems with a PCB transport height of
830 mm.