6241f.pdf - 第27页

Page 19 GS-394-02 Host Computer Interface Kit This kit is used to interface VCD/Sequencer 8 with a Host computer using the SECS/GEM Standard. The Generic Equipment Model (GEM) Standard defines a standard implementation o…

100%1 / 54
Page 18 GS-394-02
Automatic Board Handling Configurations
The VCD/Sequencer 8 is available in several material handling
configurations (left-to-right, or right-to-left):
Magazine-to-Magazine (CE-compliant), with extra cost
covers.
Vacuum Bare Board-to-Magazine (not CE-compliant).
PCB Destacker-to-Magazine.
Destacker on 29" Conveyor (not CE-compliant).
Destacker on 44" Conveyor (not CE-compliant).
Destacker on 58" Conveyor (CE-compliant) with extra cost
covers.
Magazine to PCB Destacker-to-Magazine.
Destacker on 29" Conveyor (not CE-compliant).
Destacker on 44" or 58" Conveyor. Input PCBs including
any installed components can not exceed 25.4mm (1")
thickness (CE-compliant with extra cost covers).
Internal Board Handling System (BHS) - Internal BHS for inline
systems integration is also available. Transfer direction may be
specified when ordering the machine. The front fixed rail is
standard and all operator PC board changeover adjustments are
readily accessible.
Rear Monitor
A rear monitor option is provided to allow operators and mainte-
nance personnel to view “on-screen” information from the back of
the machine. The rear monitor, which is identical to the front, is set
on a pivoting monitor arm attached to the top of the transfer cabinet.
The additional screen will aid operators in back of the machine by
displaying missing part head locations, as well as other machine
status messages. The monitor can also assist in maintenance
functions by displaying diagnostic I/O activity.
Workboard Holder
Workboard holders are required to accurately secure PC boards to
the rotary table during the insertion process when manual PCB load/
unload is being considered. Universal provides a wide range of
workboard holder products which can be ordered separately or with
a new machine purchase. When the machine is equipped with
internal BHS, a workboard holder is not required.
Page 19GS-394-02
Host Computer Interface Kit
This kit is used to interface VCD/Sequencer 8 with a Host computer
using the SECS/GEM Standard. The Generic Equipment Model
(GEM) Standard defines a standard implementation of the SECS II
(Semi Equipment Communications Standard 2) communications
interface for all semiconductor manufacturing equipment. See
SEMI International Standards document E30-93 for details. Note:
Requires customer’s Host computer to be compliant with SECS/
GEM standard SEMI E37, HSMS.
CE Non Pass Through Cover Package
In normal run mode, front covers open when board is complete
to allow PCB unload/load.
After operator changes the board, a button is pressed to close
the covers and reset the interlock and start button is pressed to
resume operation.
The covers may be opened at any time by pressing the stop
button then the open cover button.
The covers may be configured through software to open if an
error caused the machine to stop, i.e. missing part or misinsertion.
Circuitry and software unique to CE NPT cover package
improves interlock recovery time after the covers have been
opened (interlocks violated) to load/unload the PC board.
When interlock bypass key is switched to "maintenance mode",
air is removed from the cover air cylinders and the covers may
be opened and closed manually.
Compatible with existing "stand alone" workboard holders.
Supporting Documents
GS-061 Lead Tape Reel Packaging of Axial Components,
Series 2500
GS-134 Workboard Holders, Series 6810
GS-354-01 Through Hole Design Guidelines
EIA RS-296-E Lead Taping of Components in Axial Configura-
tion for Automatic Insertion
GS-167 Expanded Range Component Verifier, Series 2860
Page 20 GS-394-02
Technical Specifications
Input Specification
The axial lead components prepared and taped to the requirements
established in GS-061 “Lead Tape Reel Packaging of Axial Lead
Components,” which is an adaptation of EIA standard RS-296-E,
may be processed by the VCD/Sequencer 8. The standard input for
this machine is Class I.
Class II input may be located in only eight designated stations per
add-on module, exclusive of the Jumper Wire option. (See table on
following page.)
Class III input is not recommended for use in this machine.
Input stations are designed to accept reel or ammo pack component
packages.