Vision XP+ V AC / XP+ / XP / XS Page 31 2 Mainte nance 2.7 Clean ing the Exh aust Fi lters at the I nlet and the Outlet Service Instructions V ersion 1.3 2.7 Cleaning the Exha ust Filters at the Inlet and the Outle t Fig…

Page 30 Vision XP+ VAC / XP+ / XP / XS
2 Maintenance
2.6 Vacuum Unit
Service Instructions
Version 1.3
2.6.3 Vacuum pump filter
Fig. 2-33 Filter Vacuum pump
Fig. 2-34 Filter Vacuum pump
Fig. 2-35 Filter Vacuum pump
The filter container in front of the
vacuum pump must be opened from
time to time and the filter cleaned.
Consumbales, tool:
• Cleaning agent
• Cleaning cloth
• Cleaning bath
Procedure
1. The clamping ring of the filter
container must be opened.
The lid can be removed.
2. If the paper filter is dirty, it
must be replaced.
3. Lay the fabric filters in a
suitable cleaning agent for
cleaning.
4. After cleaning, put everything
back together and close the
clamping ring of the filter
container.

Vision XP+ VAC / XP+ / XP / XS Page 31
2 Maintenance
2.7 Cleaning the Exhaust Filters at the Inlet and the
Outlet
Service Instructions
Version 1.3
2.7 Cleaning the Exhaust Filters at the Inlet and the Outlet
Fig. 2-36 Pulling Out the Filter Housing
Fig. 2-37 Lifting the Filter Out of the Housing
Fig. 2-38 Lifting the Filter Housing
Fig. 2-39 Pull out the Filter
Consumable materials, tools:
• Oven cleaner
• Rags
• Or rinsing bath
Procedure:
1. Pull out the filter housing along
with the metallic gauze filter.
2. Loosen the wing screws and lift
the filter out of the filter housing.
3. Set the metallic gauze filter into
a rinsing bath. If a rinsing bath is
not available, the filter can be
cleaned with oven cleaner and
rags.
4. Lift the filter housing and set it
into a rinsing bath as well, or
clean it with oven cleaner and
rags.
5. After cleaning the filter, set it
back into the filter housing and
reinstall it into the system
6. Also pull out the metal gauze
filters located behind the first
hood of the machine and put it
in a rinsing bath.

Page 32 Vision XP+ VAC / XP+ / XP / XS
2 Maintenance
2.8 Water Tank - Checking and Refilling the Water Fill-
Level (Option)
Service Instructions
Version 1.3
2.8 Water Tank - Checking and Refilling the Water Fill-Level
(Option)
Fig. 2-40 Checking the Water Fill-Level
Fig. 2-41 Checking the Water Fill-Level, CN
The water tank is located behind the
second door from the right.
Consumable materials, tools:
• Water
• Antifreeze
Note!
Coolant is mixed using 1 part
antifreeze to 3 parts water.
• Watering can or similar container
Procedure:
1. The front of the water tank is
marked with the designations
MAX. and MIN.
2. When the fill-level drops to the
minimum mark, the tank must
be refilled with coolant to the
maximum mark.
3. For re-filling open the filling port
(D) at the tank and fill in the
mixed cooling liquid.
Cooling system components:
A) Cooling water controller
B) Water leak and minimum water
level sensor
C) Connection for draining water
D) Filling port
E) Temperature watchdogs
A
B
C
D
E
A
C
E
B
D