Maintenance Schedule保养计划.pdf - 第34页
Vision XP+ V AC / XP+ / XP / XS Page 43 2 Mainte nance 2.1 1 Pyrolysis Service Instructions V ersion 1.3 2.1 1 Pyrolysis 2.1 1.1 R eplacing the Granulate Fig. 2-65 Pyrolysis Uni t The pyrolysis u nit is locat ed at the b…

Page 42 Vision XP+ VAC / XP+ / XP / XS
2 Maintenance
2.10 Modulare Residue System VXS (Option)
Service Instructions
Version 1.3
2.10.3 Clean the agglomerator‘s and the cooler
Fig. 2-64 Agglomerators and cooler in the
MRS
The agglomerators and cooler has
to be cleaned in the cleaning bath
on a regular base.
Tools and consumables material:
• Cleaning bath
Procedure:
1. Pull off all pipes.
2. Open the tenter frame (push
down the handle) and take out
the cases from top to bottom.
3. Pull out the case and put it in
the cleaning bath.
4. Push the cleaned case back
into the MRS.
Filter
Agglomerator
Cooler
Tenter frame
Agglomerator

Vision XP+ VAC / XP+ / XP / XS Page 43
2 Maintenance
2.11 Pyrolysis
Service Instructions
Version 1.3
2.11 Pyrolysis
2.11.1 Replacing the Granulate
Fig. 2-65 Pyrolysis Unit
The pyrolysis unit is located at the
back of the system at the oven inlet.
Note!
The system must be cooled down before replacing the granulate, because
the granulate has a temperature of at least 500° C when the system is
running.
Fig. 2-66 Unscrewing the Door
Consumable materials, tools:
• Open-end wrench and hex key
• Granulate
• Cartridge seal
Procedure:
1. Remove the screws from the
cover and set them aside.
2. Loosen the nuts at the pyrolysis
unit and remove the cover.

Page 44 Vision XP+ VAC / XP+ / XP / XS
2 Maintenance
2.11 Pyrolysis
Service Instructions
Version 1.3
Fig. 2-67 Removing the Insulation
Fig. 2-68 Loosening the Nuts
Fig. 2-69 Removing the Insulation
Fig. 2-70 Lifting off the Grate
3. Remove the white insulation
which now becomes visible (see
Fig. 2-67). The cover of the
pyrolysis unit becomes visible
as well.
4. Loosen the nuts on the
granulate container (see
Fig. 2-68) and lift it out along
with the granulate (see
Fig. 2-69). It must be assured
that the nuts and the washers
do not fall into the pipe
connection.
5. Remove the screws which
secure the grate and lift the
grate and Gauze Filter off (see
Fig. 2-70).
6. Inspect the granulate for
contamination by breaking open
several pellets. If the granulate
is dark colored all the way
through, it has become
saturated and must be
replaced.
7. Fill the container with new
granulate under dust-free
conditions.
8. Apply copper paste to the
threads. Copper paste is heat-
resistant up to 1000° C.
If the old nuts need are no
longer usable, do not replace
them with stainless steel or zinc
plated nuts.
9. Reinstall the granulate
container by following the above
instructions in reverse order,
insert the insulation and the
seals (or replace if damaged)
and secure the cover with the
screws.