M4serviceManual_e.pdf - 第36页
3 Mechanical Section 3-6 Head Manifold Section Vacuum generator (x 4 for M4a/M4s, x3 for M4e) Silencer element (x 4 for M4a/M4s, x3 for M4e) Air filter assy. (x 4 for M4a/M4s, x3 for M4e) Filter element (x 4 for M4a/M4s,…

3 Mechanical Section
3-5
③ The head manifold section will be exposed, enabling easy inspection.
ACTION: Installation
Installation of each head cover must be carried out in reverse order of removal.
NOTE: When attaching each head cover , tighten the plastic screws firmly to fix the head cover to the head base
securely. If the head cover is not secured sufficiently, it may come off during operation, causing serious
accidents.

3 Mechanical Section
3-6
Head Manifold Section
Vacuum generator (x 4 for M4a/M4s, x3 for M4e)
Silencer element (x 4 for M4a/M4s, x3 for M4e)
Air filter assy. (x 4 for M4a/M4s, x3 for M4e)
Filter element (x 4 for M4a/M4s, x3 for M4e)
Solenoid valve (x 8 for M4a/M4s)
(x 6 for M4e)
*The drawing above is for M4a. Mechanical constructions of M4e and M4s are almost same as
M4a.

3 Mechanical Section
3-7
Head Manifold Section
■ Air Passage
To maintain the designed accuracy and component-placement rate of the machine, clean the air passage
between the air filter assy. and nozzle holder periodically.
ACTION: Carry out vacuum break operation for a few seconds with the nozzle removed.
● Cleaning interval
Approx. once a week
■ Air Filter
ACTION: Remove the filter element from the air filter assy. and remove dust and dirt collected inside the assy. by air
blowing. Then, check the white air element for dirt. If it is excessively dirty, replace it with a new one. If air
filter assy. case is dirty, wash it with water or diluted neutral detergent, and dry it well. If there are cracks on
the case, replace the air filter assy., since the cracks will cause air leakage.
NOTE: Do not use alcohol or any organic solvents to wash the air filter assy. case. Using those solvents may cause
damage or degradation of the case because it is made of polycarbonate.
● Inspection interval
Once a week, and when a choking error occurs
Part Name
Part No. Remark
FILTER ELEMENT LC1-M71A9-00X Filter element
AIR FILTER ASSY. LC1-M71A4-00X Air filter Assy.
■ Vacuum Generator
ACTION: Visually check the silencer element, and if it is excessively dirty, replace it with a new one. Also measure
the maximum air pressure to inspect whether the vacuum generator can generate vacuum properly.)
Inspection for Head/Nozzle Clogging and Solenoid Valve
● Inspection interval
Once a week
Part Name
Part No. Remark
SILENCER ELEMENT LG0-M71A8-00X Silencer element
GENERATOR,VACUUM LG0-M71A3-00X Vacuum generator