SIPLACE D系列Servicemanual.pdf - 第69页

Service Work D3 Gantry Servicemanual (internal version) SIPLACE D Series 69 4.1.3.8 Replacing the X Drive (Primary ) [03039726-xx] Required equipment  Service Pack X drive (0037743 7- xx) for SIPLACE HF/X machines –X d …

100%1 / 118
Service Work
Gantry D3
68 Servicemanual (internal version) SIPLACE D Series
Installation
X Clean the reading surface of the incremental
encoder with a cloth and ethanol or with a
cleansing tip.
X Loosely fasten the incremental encoder (2)
with three fastening screws (3).
X The incremental encoder must be aligned with
a 0.4 mm gap to the scale. Use the
corresponding thickness gauge (plastic).
3
4
1
2
4-17: Casting marks on the incremental encoder
X You must set the exact height to the scale.
X Align the incremental encoder, using the two
casting marks (arrows), which mark the read
area.
X Tighten the fastening screws.
X Reconnect to the electricity supply.
ATTENTION: Check how the cables
are run!
Make sure that the axes can be moved
without damaging the cables.
X Fasten them with cable ties.
X Move the gantry into the end stopper and
check that the buffer does not come into
contact with the cable.
Service Work
D3 Gantry
Servicemanual (internal version) SIPLACE D Series
69
4.1.3.8 Replacing the X Drive (Primary) [03039726-xx]
Required equipment
Service Pack X drive (00377437-xx) for SIPLACE HF/X machines
–X drive
4 x dismantling screws
8 x lock screws (M4x60)
Templates for Twin Head and DLM2
6 grub screws M4x6-ST
Plastic thickness gauge 0.4 mm (approx. 50 cm long and 10 cm wide)
Foam rest 500 mm x 50 mm x 20 mm
Xenon flashlight (non-magnetic)
Torque wrench with socket-head adapter
Loctite 241
Removal
NOTE:
The service pack for the X drive 00375245-01 only fits HF machines up to machine number
A219.
Legend
1. X drive (primary) with head mount
2. X mount with trailing cable
3. Head adapter board
4. Mount with PCB camera
5. Head Board
X Dismantle the placement head.
X Remove the head adapter board (3). The X
mount fixtures (2) are now accessible.
X Unplug the following cables from the head
board (5) and remove them from the X mount
(2):
X motor cable
X axis scanner head
Temperature sensor
5
5
1 4
3
2
Service Work
Gantry D3
70 Servicemanual (internal version) SIPLACE D Series
X Unplug the proximity switch cable (2) and pull
it forwards, out of the head mount.
X Undo the 8 screws (4 x at front/ 4x at back)
fastening the X mount (1) and pull these up
and out, together with the trailing cable.
X Fasten the X mount at a suitable point.
DANGER:
Make sure that the flat ribbon cable and
the pneumatic hoses are not rubbed
against any parts or folded. Look out for
sharp edges.
2
1
X Undo the 4 screws fastening the PCB camera
mount (1). Remove the complete unit,
including PCB camera (3) and damping
bracket (2).
X Fix the mount (1) to a suitable point on the
machine base. Take care not to damage the
camera.
1
3
2
Legend
1. Insert 4 x dismantling screws
2. 4 x lock screws M4x60
X On each of the 4 sides, insert 1 dismantling
screw (1) and tighten as far as the stopper.
X Remove one fastening screw (2) from each of
the 4 sides.
X Replace this fastening screw with a M4x60
lock screw in each case. This prevents the
motor from falling down when pressure is
applied to it.
1
2
2
1
2