SIPLACE D系列Servicemanual.pdf - 第96页
Service Wo rk Placement Heads Replacing the Twin Head Hoses 96 Servicemanual (internal ve rsion) SIPLACE D Series X Place the elbow into its holder. X Fix the elbow loosely with the fastening screw (1) . Carefully move t…

Service Work
Replacing the Twin Head Hoses Placement Heads
Servicemanual (internal version) SIPLACE D Series
95
X Disconnect the long hose (1) at the top.
X Disconnect the short hose (2) from the rotary
supply (1) .
X Replace the short hose at the elbow with a
new one.
This is 26 mm long.
NOTE:
X Fit the hoses approx. 4 - 5 mm onto
the respective connections.
X Fit the short hose for the elbow onto the rotary
supply.

Service Work
Placement Heads Replacing the Twin Head Hoses
96 Servicemanual (internal version) SIPLACE D Series
X Place the elbow into its holder.
X Fix the elbow loosely with the fastening screw
(1).
Carefully move the elbow, so that the screw
engages with the notch (2) .

Service Work
Replacing the Twin Head Hoses Placement Heads
Servicemanual (internal version) SIPLACE D Series
97
X Move the short hose between the elbow and
the rotary supply.
The rotary supply and the Z axis must be
centered in their guidance (1) .
Press the hose onto the connection or away
from it, until the axis is positioned in the center.
An eccentric position of the Z axis can alter the
balance of forces and lead to placement
errors.
The short hose must also run horizontally (2)
between the elbow and the rotary supply.
X After successfully adjustment, tighten the
screw fastening the elbow.
X Reconnect the long hose at the top.
X Reconnect the flat ribbon cable connector (1).
X Place the flat ribbon baffle on the flat ribbon
cable.
X Place the return unit stopper (2) onto the flat
ribbon baffle.
X Insert the two screws (3) into the stopper.
X Align the flat ribbon baffle to the flat ribbon
cable.
ATTENTION:
The baffle and cable must run parallel
to one another (1)!