00196624-04_Service Manual WPC5_6_EN_01-2019.pdf - 第103页
Service Manua l WPC5 / WPC6 Page 3-103 3.7.14 Sensor 15 NSM-Modul (WPC6) – Safety flap open Spare Part • Sensor safet y flap open [03056958- xx] Removal / Install ation ➢ Remove the cover on the load unit (see "3.…

Service Manual WPC5 / WPC6
Page 3-102
➢ Fix the load axis drive motor (see "3.5.2 Replacing the Load Axis Drive Motor" [➙
3-34]).
➢ Fit the cover back on the loading unit.
➢ Loosen the counternut fastening
the sensor on the underside of the
base plate and unscrew the sensor
(1).
➢ Screw the new sensor into place.
➢ The sensor should protrude at least
0.2 mm above the table plate.
➢ Use a counternut to fix the sensor
on the underside
(1).
➢ Reconnect connector X4 to the
circuit board.

Service Manual WPC5 / WPC6
Page 3-103
3.7.14 Sensor 15 NSM-Modul (WPC6) – Safety flap open
Spare Part
• Sensor safety flap open [03056958-xx]
Removal / Installation
➢ Remove the cover on the load unit (see "3.5.1.1 Remove the Cover on the Load Unit" [➙
3-
32]).
➢
Loosen the screws marked at 1 to 4
and lift off the cover.
➢ Disconnect connector X3 for the
safety flap when open from the
circuit board.

Service Manual WPC5 / WPC6
Page 3-104
➢ Fit the cover back on the loading unit and screw tight.
See also...
@
3.5.2
Replace the Load Axis Drive Motor [➙ 3-34]
➢ Unscrew the sensor (1) from its
mount.
➢ Screw the sensor into its mount.
➢ Use a feeler gauge to set the
distance between the safety flap
and the sensor to 0.2 mm.
➢ Reconnect connector X3 to the
circuit board.