Service Manua l WPC5 / WPC6  Page 4-131 ➢ Insert the calibration pi n (see figure above) an d continue with Commit (1). ➢ Remove the cal ibration pin and confirm the new transfer positio n with Finish (1).

100%1 / 143
Service Manual WPC5 / WPC6
Page 4-130
4.2.5 Teaching the WPTC Transfer Position
Select the feed axis (1).
Select the function
Teach WPTC alignment position
(2).
Select
Next
(3).
Insert the calibration pin Adjusting gauge small WPC [03052363-02] on the front end of the
feed axis (1).
Adjusting gauge small WPC
[03052363-02]
Service Manual WPC5 / WPC6
Page 4-131
Insert the calibration pin (see figure above) and continue with
Commit
(1).
Remove the calibration pin and confirm the new transfer position with
Finish
(1).
Service Manual WPC5 / WPC6
Page 4-132
4.3 Calibrating the Load Axis (WPC6 only)
Before calibration, remove all waffle-pack tray carriers (WPTCs) from the WPC.
Calibration of the load axis includes the following functions:
"4.3.2 Teaching the Zero Point Position" [
4-133]
"4.3.3 Reference Proximity Switch (Bero)" [
4-135]
"4.3.4 Calibrating the Limit Switch" [
4-137]
Load axis order of settings
If the limit switches or sensors are replaced, you will need to recalibrate or reset these
accordingly.
A complete recalibration is only needed if the zero point position is changed.
The function for the
limit switch +
and
limit switch
specified in the software is assumed by the
end position stoppers (bumpers) at the machine end and tower end.