00196624-04_Service Manual WPC5_6_EN_01-2019.pdf - 第118页

Service Manua l WPC5 / WPC6  Page 4-118 4.1.3 Reference Proximity Switch (Bero) ➢ Remo ve all waffle -pack tray c arriers (WPTC) from the WPC. ➢ S elect the lifting axis (1). ➢ S elect the function Reference bero (2). ➢…

100%1 / 143
Service Manual WPC5 / WPC6
Page 4-117
Use the arrow keys (2) to select the required pitch (1) (0.1 mm in this example).
Use the arrow keys to move the tower so that the tray can be correctly moved from the feed
axis into the tower.
Continue with
Next
(3).
Follow the instruction shown and confirm the changes made with
Finish
.
Service Manual WPC5 / WPC6
Page 4-118
4.1.3 Reference Proximity Switch (Bero)
Remove all waffle-pack tray carriers (WPTC) from the WPC.
Select the lifting axis (1).
Select the function
Reference bero
(2).
Select
Next
(3).
Confirm the new reference point proximity switch with
Finish
.
Service Manual WPC5 / WPC6
Page 4-119
4.1.4 Calibrating the Limit Switch
The plus and minus position of the limit switches need to be calibrated.
Remove all waffle-pack tray carriers (WPTC) from the WPC.
Select the lifting axis (1).
Select the function
Calibrate limit switch
- (2).
Select
Next
(3).
Calibrating the limit switch -
Confirm the new position at which the limit switch triggers with
Finish
.
Calibrating the limit switch +
Select the lifting axis (1).
Select the function
Calibrate limit switch +
and continue with the same procedure as that
used for calibrating the limit switch.