00196624-04_Service Manual WPC5_6_EN_01-2019.pdf - 第127页
Service Manua l WPC5 / WPC6 Page 4-127 ➢ Confirm the new ref erence point proximity s witch with Finish (1). Setting the Drive r Cam ➢ Loosen the screw (1) , fastening the cam to the dr iver. ➢ Correct the position of …

Service Manual WPC5 / WPC6
Page 4-126
4.2.3 Reference Proximity Switch (Bero)
➢ Select the feed axis (1).
➢ Select the function
Reference bero
(2).
➢ Select
Next
(3).
➢ Follow the instruction shown and continue with
Commit
(1).

Service Manual WPC5 / WPC6
Page 4-127
➢ Confirm the new reference point proximity switch with
Finish
(1).
Setting the Driver Cam
➢ Loosen the screw (1), fastening the cam to the driver.
➢ Correct the position of the cam by moving it accordingly in either the – or + direction.
➢ Retighten the screw (1) and repeat the measuring steps (see "3.7.5 Replace the Reference
Sensor, Feed Axis [03057837-xx]" [➙ 3-79]).
➢ Repeat the individual steps until no more error messages appear.

Service Manual WPC5 / WPC6
Page 4-128
4.2.4 Calibrating the Limit Switch
The plus and minus position of the limit switches need to be calibrated.
Calibrating the limit switch -
➢ Select the feed axis (1).
➢ Select the function
Calibrate limit switch -
(2).
➢ Select
Next
(3).
➢ Follow the instruction shown and continue with
Commit
(1).