00196624-04_Service Manual WPC5_6_EN_01-2019.pdf - 第127页

Service Manua l WPC5 / WPC6  Page 4-127 ➢ Confirm the new ref erence point proximity s witch with Finish (1). Setting the Drive r Cam ➢ Loosen the screw (1) , fastening the cam to the dr iver. ➢ Correct the position of …

100%1 / 143
Service Manual WPC5 / WPC6
Page 4-126
4.2.3 Reference Proximity Switch (Bero)
Select the feed axis (1).
Select the function
Reference bero
(2).
Select
Next
(3).
Follow the instruction shown and continue with
Commit
(1).
Service Manual WPC5 / WPC6
Page 4-127
Confirm the new reference point proximity switch with
Finish
(1).
Setting the Driver Cam
Loosen the screw (1), fastening the cam to the driver.
Correct the position of the cam by moving it accordingly in either the or + direction.
Retighten the screw (1) and repeat the measuring steps (see "3.7.5 Replace the Reference
Sensor, Feed Axis [03057837-xx]" [ 3-79]).
Repeat the individual steps until no more error messages appear.
Service Manual WPC5 / WPC6
Page 4-128
4.2.4 Calibrating the Limit Switch
The plus and minus position of the limit switches need to be calibrated.
Calibrating the limit switch -
Select the feed axis (1).
Select the function
Calibrate limit switch -
(2).
Select
Next
(3).
Follow the instruction shown and continue with
Commit