00196785-02_IM_Taceability_3.3_EN.pdf - 第31页
Installation of Trace Service and Trace Monitor Installation Trace Monitor Installation Manual SIPLACE Traceability 3.3 31 ► Click on the Install button to start the actual installation of the SIPLACE Explorer Traceabili…

Installation of Trace Service and Trace Monitor
Trace Monitor Installation
30 Installation Manual SIPLACE Traceability 3.3
►Close all other programs and then click on Next to
continue.
►Before the SIPLACE Explorer Traceability Option can
be installed, Trace Monitor and SIPLACE Explorer
must be installed on your network environment. If
both of these applications are already installed, in-
stallation of the SIPLACE Explorer Traceability Op-
tion will begin automatically. The SIPLACE Explorer
Traceability Option must be installed on the same
computer as SIPLACE Explorer; Trace Monitor can
be installed on a different computer.
►If the SIPLACE Explorer Traceability Option installa-
tion procedure is unable to locate SIPLACE Explorer
on your computer, you will see the following dialog
box.
►Specify the SIPLACE Explorer installation folder here.
If SIPLACE Explorer has not yet been installed on
your computer, you can click on Cancel to terminate
the SIPLACE Explorer Traceability Option installation
procedure.
►Install Trace Monitor and SIPLACE Explorer on your
network environment and then restart the SIPLACE
Traceability installation procedure.
►If Trace Monitor and SIPLACE Explorer are already
installed on your system, the installation procedure
will continue.
►Read the license conditions. Click on I accept ... to ac-
cept and on I do not accept ... if you do not want to
accept. If you click on I do not accept ..., the installa-
tion procedure will be terminated.
⇨ The following dialog box will be shown:

Installation of Trace Service and Trace Monitor
Installation Trace Monitor
Installation Manual SIPLACE Traceability 3.3 31
►Click on the Install button to start the actual installation
of the SIPLACE Explorer Traceability Option.
Once the installation procedure has started, the following
dialog box will open:
►Click on Finish. The SIPLACE Explorer Traceability
Option is now available on the SIPLACE Explorer fac-
tory website.

Installation of Trace Service and Trace Monitor
Trace Monitor Troubleshooting
32 Installation Manual SIPLACE Traceability 3.3
5.3.2 Troubleshooting
5.3.2.1 Port Configuration after Changing Tomcat Port Number
The Tomcat port number needs to be changed (as described below) in the following cases:
▪ If the port is changed for website generation via Start menu -> SIPLACE Traceability -> Trace Mon-
itor the Install Monitor Webapplication.
▪ If the standard port number 8080 is already in use and you do not want to use it again for this job
(website access).
►To change the port number, find the following lines in the file
<Tomcat-location>\conf\server.xml
►and change 8080 to your choice of port number as shown below:
<!-- Define a non-SSL Coyote HTTP/1.1 connector on the port specified dur-
ing installation-->
<Connector port="8080" maxThreads="150" minSpareThreads="25" maxSpare-
Threads="75" enableLookups="false" redirectPort="8443" acceptCount="100"
debug="0" connectionTimeout="20000" disableUploadTimeout="true" />
►Change the specified port number 8080 (Connector port="8080") to the required port number
(Connector port="YourPort"). For further information about port number, please contact your
system administrator.
►To make Tomcat your default web server, set the port number to 8080.
5.3.2.2 Collation conflicts when restoring database backup
When restoring the database backup, the SQL Server must have the same collation as the database
backup. Otherwise run time errors and collation conflicts will occur when performing data query in Trace
Monitor.
►In case of collation conflicts we recommend you to recreate the SQL Server.
NOTICE
Default port
By default, Tomcat is installed on port 8080. This means that your users will access your web-
site as follows: http://yourServerName:8080/yourWebsite.
NOTICE
Add port number to URL
The port number specified in this xml file needs to be added to the URL address each time you
generate a website: http://yourServerName:yourPort/yourWebsite.