Installation of Trace Service and Trace Monitor
Trace Monitor Troubleshooting
32 Installation Manual SIPLACE Traceability 3.3
5.3.2 Troubleshooting
5.3.2.1 Port Configuration after Changing Tomcat Port Number
The Tomcat port number needs to be changed (as described below) in the following cases:
▪ If the port is changed for website generation via Start menu -> SIPLACE Traceability -> Trace Mon-
itor the Install Monitor Webapplication.
▪ If the standard port number 8080 is already in use and you do not want to use it again for this job
(website access).
►To change the port number, find the following lines in the file
<Tomcat-location>\conf\server.xml
►and change 8080 to your choice of port number as shown below:
<!-- Define a non-SSL Coyote HTTP/1.1 connector on the port specified dur-
ing installation-->
<Connector port="8080" maxThreads="150" minSpareThreads="25" maxSpare-
Threads="75" enableLookups="false" redirectPort="8443" acceptCount="100"
debug="0" connectionTimeout="20000" disableUploadTimeout="true" />
►Change the specified port number 8080 (Connector port="8080") to the required port number
(Connector port="YourPort"). For further information about port number, please contact your
system administrator.
►To make Tomcat your default web server, set the port number to 8080.
5.3.2.2 Collation conflicts when restoring database backup
When restoring the database backup, the SQL Server must have the same collation as the database
backup. Otherwise run time errors and collation conflicts will occur when performing data query in Trace
Monitor.
►In case of collation conflicts we recommend you to recreate the SQL Server.
NOTICE
Default port
By default, Tomcat is installed on port 8080. This means that your users will access your web-
site as follows: http://yourServerName:8080/yourWebsite.
NOTICE
Add port number to URL
The port number specified in this xml file needs to be added to the URL address each time you
generate a website: http://yourServerName:yourPort/yourWebsite.
Installation of Trace Service and Trace Monitor
Troubleshooting Trace Monitor
Installation Manual SIPLACE Traceability 3.3 33
5.3.2.3 Generating a Web site is denied
If the generation of the Monitor web site fails, a corresponding error message is displayed.
This is only true for Windows Vista and Windows 7 if the Web site is regenerated manually using the
Install Monitor Webapplication shortcut in the start menu. You need administrator rights to generate the
Web site. In Windows Vista you don’t have administrator rights in Trace Monitor even if you are member
of a user group with administrator rights.
Workaround 1
►Change the rights of the Trace Monitor installation folder (e.g. C:\Program Files\SIPLACE\SI-
PLACE Traceability Monitor) manually to Full control.
Workaround 2
Start the Monitor Configuration Tool with administrator rights:
►Navigate to the installation folder of Trace Monitor (e.g. C:\Program Files\SIPLACE\SIPLACE
Traceability Monitor)
►Right-click on InstallTHMonitor.exe
►Select Run as Administrator and confirm the following security message with Yes or Allow.
Installation of Trace Service and Trace Monitor
Trace Monitor Troubleshooting
34 Installation Manual SIPLACE Traceability 3.3