00193733-02.pdf - 第56页

2 Assembly Instructions PCB Camera, Multicolor SIPLACE F5 HM SIPLACE F5 HM 2.6 Assembly Terminal panels and Illumination cable 05/2007 Edition 56 2.6.2 Assembling in the T erminal Panel, LH Side 2.6.2.1 Changing the &quo…

100%1 / 88
SIPLACE F5 HM 2 Assembly Instructions PCB Camera, Multicolor SIPLACE F5 HM
05/2007 Edition 2.6 Assembly Terminal panels and Illumination cable
55
2.6.1.2 Conducting the Wiring in the Terminal Panel, Right Side
: Remove the cover from the horizontal and vertical cable pit.
: Remove the green strand running from rectifier module A2: X7 to terminal X207-1
(layout A2: see Abb. 2.6.2). The terminal X207-1 is then not in use.
: Run the cables W1 to W5 from the assembly kit as shown in the overview, Fig. 2.13.7.
Prefabricate the cables as much as possible.
NOTE:
You will need a size 1 screwdriver to disconnect and make the Catch terminal connections and
terminal connections X 207. 2
: Lay and wire the new cables W1 to W5 as shown in circuit diagram Fig. 2.13.8 AND, while
doing so, assemble cables W2 and W3 as follows:
Install a twin connector sleeve at cable end W2 that will be connected to X207-3 and at ca-
ble end W3 that will be connected to X207-5.
Use the crimp pliers to fasten each of the two strands bl/bk in the twin connector sleeve.
Clamp the cables W2 thus assembled to X 207-3 and W3 to X 207-5.
: Make certain that all connections are firmly seated and are correctly allocated.
2
2 Assembly Instructions PCB Camera, Multicolor SIPLACE F5 HM SIPLACE F5 HM
2.6 Assembly Terminal panels and Illumination cable 05/2007 Edition
56
2.6.2 Assembling in the Terminal Panel, LH Side
2.6.2.1 Changing the "Illumination" Cables
The F5 HM has 2 "illumination" cables: 2
Cable "illumination, gantry 1": Item no. 00244260-xx
Cable "illumination, gantry 2": Item no. 00244261-xx
These cables must be changed first, as described below.
Abb. 2.6.3 Terminal Panel, LH Side, Layout of the Illumination Cables, Gantries 1 and 2
: Open the machine frame doors for terminal panel, LH side.
: Use the circuit diagram Fig. 2.13.6 and change the two cables "illumination, gantry 1" and "2"
as follows:
Separate the strands wh, gn, gr, bl which are clamped to terminal X212 - 4 with a connector
sleeve.
Use the crimping pliers. Now clamp these strands separately as follows, each in a twin con-
nector sleeve from the assembly kit (Section 2.4.3):
- wh with gn
- gr with bl
: Clamp the 2 changed "Illumination" cables on the terminal panel:
the strands wh, gn -> to terminal X212 - 4 (+ 24V),
the strands gn, bl -> to terminal X212 - 9 (+ 50V)
3
4
X212
SIPLACE F5 HM 2 Assembly Instructions PCB Camera, Multicolor SIPLACE F5 HM
05/2007 Edition 2.6 Assembly Terminal panels and Illumination cable
57
2.6.3 Removing PCB Camera (Normal Illumination) incl. Oblique Illumination
Abb. 2.6.4 Loosening Cable Ties, Removing Subgantry PCB Camera (Using HS-50 as an Example)
: Remove the cover over the placement heads (undo 5 screws on each).
Refer to the note in Abschn. 2.1 regarding the continued use of the covers.
: Cautiously undo the cable ties along the cable harness (Fig. 2.6.10):
: In case of initial situation "old PCB camera with head PCB moduar": On the "Vision board, mo-
dular" unplug the connectors of the subgantry PCB camera (normal illumination) and - if pre-
sent - the oblique illumination (see Fig. 2.13.4 and Fig. 2.13.5).
Cable, PCB camera (old) -> X4
Cable, illumination for PCB camera -> X6
Cable, oblique illumination -> X5
Cable harness
Cable ties