FK-9F98-27 CP-7 Series Training Text for Service Engineers
Edition 6.0 Chapter 10. Options [4/6]
3. At 0 degrees, press the [DUST] button on the amplifier. If the display indicates “---“, the
sensor windows are probably dusty or soiled etc.. Ensure the sensor windows are clean by
wiping them thoroughly with a dry lint free cloth. Press [DUST] again to display the counter.
Clean sensor
windows here
Figure 7
4. Press [INSPECT] to measure.
Check that the amplifier displays “000” (The DUST LED will be ON at this time)
On the main display, the measurement results are displayed “about 1.03V” (“Axis 0”), adjust
the Offset Volume pot on the amplifier so the ”Axis 0” voltage reading is between 0.950 to
1.050V.
5. At a cam angle of 197 degrees, block the sensor completely, then press [INSPECT].
Verify that the amplifier displays “8.00”. If “8.00” does not appear, then the sensor is not
completely blocked.
The measurement results will display at “about 8.97V”. (”Axis 0” voltage reading)
Adjust the Gain Volume on the amp so the ”Axis 0” voltage reading is between 8.950 to
9.050V.
Figure 8
Gain Adj.
OffsetAdj.
Portable Monitor
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
CS Section
10-4

FK-9F98-27 CP-7 Series Training Text for Service Engineers
Edition 6.0 Chapter 10. Options [5/6]
6. Remove the blockage at the sensor and return the cam angle to 0 degrees.
Press [INSPECT] again to check that the voltage value is less than 1.5V.
7. Press [EXIT].
8. Move Holder A to station 9.5 at 0 degrees and install the nozzle reference jig.
Nozzle Reference Jig
(Jig No.: DCPJ0620)
Figure 9
9. For automatic measuring of the nozzle jig height, Press: [Maintenance] → [Calibration] → [Part
Nozzle Reference ] → [Start].
10. Check that the measurement results are within 1.00 ± 0.3 (0.7 to 1.3)
* Verify that the displayed amplifier value and the measurement results on the display are the
same value.
11. Press: [CLOSE] on the display. A message appears to save proper data, press [YES].
10.1.4 How to avoid problems while adjusting the voltage
1. Do not press the buttons on the unit while the [MODE] LED is flashing (when the raw image is
displayed). Press [MODE], and the LED will turn OFF.
2. The [DUST] LED indicates an abnormal condition. Press [DUST] at cam angle 0 degrees and
the LED will turn OFF.
10.1.5 Amplifier SW and LED functions
[MODE] Switches the monitor output display.
LED ON: Raw Image LED OFF: Memory Image
[INSPECT] Press when issuing measurement commands.
(Measurement should be carried out at 0 degrees)
[DUST] Press this button when registering the black image.(sensor blocked)
(Registered at 0 degrees) The LED will turn ON if an error occurs.
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
CS Section
10-5

FK-9F98-27 CP-7 Series Training Text for Service Engineers
Edition 6.0 Chapter 10. Options [6/6]
10.2 Vacuum Backup Pin Adjustment
1. Verify that the electrical modification is completed and the Z-axis table, backup pins and
backup plate are arranged for vacuum type backup pins.
2. Adjust the positive pressure timer speed controller 3 revolutions from the fully closed
position.
3. Adjust the positive pressure speed controller to 1/4 from the fully closed position.
Turn ON I/O (Y022) with a board clamped on the XY table. If there is a lot of noise from
the vacuum generator when the vacuum is OFF, adjust the controller to where the noise is
minimal.
Low
Positive pressure timer
speed controller
Figure 10
High
Positive Pressure
speed controller
LowHigh
4. To enable the vacuum backup pin function, follow the command path below:
Press: [Maintenance] Æ [Configuration] Æ [Basic] Æ [Special Configuration Data] Æ
[Vacuum Backup Function] Æ ON
Note: When re- installing the system software, the default setting is set to Not Used.
Therefore, be sure to set to Used after installing the system software.
Figure 11
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
CS Section
10-6