00196622-03_OM_WPC5_6_EN.pdf - 第38页
Setting up and Commissioning Adjusting the WPC Height from 900mm to 930mm 4.2.4 Undocking t he WPC5/WPC6 38 Operating Manual SIPLACE WPC5/WPC6

Setting up and Commissioning
4.2.4 Undocking the WPC5/WPC6 Adjusting the WPC Height from 900mm to 930mm
Operating Manual SIPLACE WPC5/WPC6 37
► Screw the settings screws out until the WPC lies on the blocks.
► Through the machine base, screw the four counter screws into the upper part.
▪ For 900 mm height, the distance is 20 mm.
▪ For 930 mm height, the distance must be 50 mm.
The adjustment to 930 mm can be simplified by using
four spacer blocks (each one 50 mm in height) (1).
► Insert the four spacer blocks. Make sure that there is
enough play around the blocks to remove them later
on.
NOTICE
Setting screw
Make sure not to screw out the setting screw too far; it must also lie on the block.
Setting up and Commissioning
Adjusting the WPC Height from 900mm to 930mm 4.2.4 Undocking the WPC5/WPC6
38 Operating Manual SIPLACE WPC5/WPC6

Operator Tasks
Controls and Displays
Operating Manual SIPLACE WPC5/WPC6 39
5
5 Operator Tasks
Operator Tasks
5.1
5.1 Controls and Displays
Controls and Displays
The main switch and the EMERGENCY STOP button are located on the back of the Wafflepack
Changer.
Main power switch in the OFF position
The main power switch disconnects the three phases U, V and W from the power supply.
Main power switch in the ON position
After switching on the main switch, the power supply provides the voltages needed to operate the WPC.
EMERGENCY STOP button
When you press the EMERGENCY STOP button, the power supply to the lifting and feed axes is inter-
rupted and the whole system comes to a halt.
WARNING
Hazardous Voltages
The following power supply components still carry potentially lethal voltages even if the main
power switch is switched off:
- Feed in terminals
- Line filter
- Cable connection terminals for main switch
Therefore incorrect use of the machine may lead to death or severe injury and considerable
damage to equipment.
► Always follow the applicable accident prevention and DIN regulations (particularly DIN EN
60 204, part 1) and the applicable regulations in your own country.
► The safety covers on the Wafflepack Changer may ONLY be opened by appropriately qual-
ified and trained personnel.
1. Safety door of the tray storage unit
2. Flap for loading the Non-Stop Module (only at WPC6)
3. EMERGENCY STOP button
4. Main power switch
5. Crank handle for lifting or lowering the trolley carriage
6. Non-Stop Module start button (only WPC6)