Operator Tasks
5.5.1 Basic View Maintenance and Service
Operating Manual SIPLACE WPC5/WPC6 43
5.4
5.4 Maintenance and Service
Maintenance and Service
See also the document "Maintenance guide WPC4/WPC5WPC6" [item no. 00195347-xx].
5.5
5.5 Functions at the Station Computer (SR703.xx)
Functions at the Station Computer (SR703.xx)
5.5.1
5.5.1 Basic View
Basic View
The WPC icon (1) can be displayed in various colors in the basic view. These mean:
The display applies equally to the WPC and to the feeder modules, which are set up on the remaining
feeder locations, next to the WPC.
The basic view shows the SIPLACE machine from above.
The PCB conveyor runs through the center. The locations
are positioned on the right and left. The location of the
WPC is shown as item (1) in this example.
WPC color Component color Meaning
Gray - - - No component in WPC / feeder module configured or no setup defined.
Gray Green A setup is present and one or more components are defined for this lo-
cation.
Gray Red / green Empty waffle pack trays/ tracks in WPC / feeder module
Red Red / green Track error at this location (WPC / feeder module)
Yellow Red / green Production was continued although the WPC is in the refill position.
Operator Tasks
Functions at the Station Computer (SR703.xx) 5.5.2 WPC5 Functions
44 Operating Manual SIPLACE WPC5/WPC6
5.5.2
5.5.2 WPC5 Functions
WPC5 Functions
In the tool bar of the main view click on the icon (1) for
the functions Feeder, Locations….
Click on the icon (2). The user interface will switch to
the view Functions > Locations > WPC.
Click on the icon (3) for the WPC5 at the relevant lo-
cation (location 1 here).
The Setup > Locations > WPC view will be shown for
the selected Location.
NOTICE
WPC icon
The icon for the WPC5 will only be shown for the location if a WPC5 is really present there.
NOTICE
Main view
If there is a setup available for the WPC5, this will be shown as an icon in the diagram of the
relevant WPC5 in the main view.
If you click on this, the WPC view will be opened for the WPC5 at the location.
Operator Tasks
5.5.2 WPC5 Functions Functions at the Station Computer (SR703.xx)
Operating Manual SIPLACE WPC5/WPC6 45
5.5.2.1
5.5.2.1 "WPC" View
"WPC" View
Waffle pack tray details
Level 1 to 28.
Magazine Number of waffle pack trays
Component level Current and maximum component level in the waffle pack tray.
Component name Name of the component in the waffle pack tray
Status Status display or current component level of the waffle pack tray
Functions
Reference run Moves the lifting and feed axis into a defined position.
Refill position In Move to refill position: Moves to the position in which the waffle pack tray
carriers for all levels can be replaced. Components can no longer be picked
up from the WPC.
Exit refill position: Moves the complete WPC back to working position.
Components can be picked up again.
FIFO strategy Enabled: As soon as pickup has been performed once from a waffle pack
tray on a replacement track, this will be emptied completely before the ac-
tual track is used again.
Disabled: The components are picked up on a travel path optimized basis.
With occupancy check The existing waffle pack tray carriers are compared to those specified in the
setup.
Select All This selects all levels in the selected cassette.
Deselect All This disables the currently selected levels.
Activate/Deactivate This enables or disables all the trays in the cassette for pickup, depending
on the state of the selected cassette.
Prepare level The lifting axis moves the selected level to the feed axis position and the
waffle pack tray carrier will be moved to the staging position.
Set full The maximum number of components is entered as the current filling level
and the tray is put back into operation.
Details Opens a dialog box in which you can adjust the data for the selected waffle
pack tray.
Correct position (can only be enabled from operator level "Service"). Starts a dialog box for
manual correction of the component pickup position.