JANETS_SPE_EN.pdf - 第23页

JaNets Prod uct S pecific ations 2. JaNets Exter nal Output Fu nction Overview 2-3 Devices and op tions required fo r each function The devices and options (OP) of the external output function of JaNets are shown b elow …

100%1 / 35
JaNets Product Specifications
2. JaNets External Output Function Overview
2-2
Overview of the Functions
The functional overview of the External Output Function is described below.
Table 1.2.1 Functional overview of the External Output Function
Function name
Overview
How to Use Each
Function
Outputs error information.
Outputs backed-up data such as information output to an external system and the environ-
mental settings.
Line configuration infor-
mation output function
Outputs the information on the line configuration and machine setting which are controlled
by Shop floor setup.
Machine monitoring
function
Outputs information on production management.
Outputs the status information of the machine.
Outputs information on the tact.
The machine event
notifying function *1
Outputs the information (machine production start/end information, etc.) related to machine
events.
The mis-placement
preventive function *2
Checks the interrelation among the feeder, placement position and component (reel) and
mis-placement.
Extracts the component names and component serial by using the standard expression from
the character string of a bar code scanned by the machine side.
Extends the output information of the machine event notifying function and gives machine
reel information and residual number of components.
Off-line Setup function *3
Creates information on loading of a feeder or a component for a container (such as a bank
and a stacker) to load it to machines collectively.
Traceability function *4
Extends the output information of the machine event notifying function and gives traceability
information (PWB code information and placement information).
IFS-NX linkage function
*5
Obtains information from IFS-NX to output machine event information and/or machine reel
information.
Parts stock management
function *6
Creates component lists required for production from the optimized production program.
(The component lists can be registered as BOM information by importing them into ISM.) *8
Updates the residual number of components registered in ISM at the end of production of
each PWB. *6
Performs automatic delivery. (Estimates “No components” at the end of production about
each PWB and sends a delivery order to ISM before occurrence of “No components”.) *7 *9
Machine operation
function
Requests the machine to temporarily stop, abort the current operation or perform a cycle
stop.
Asks an external system whether it can produce a PWB at start of production as the start
interlock function of the machine too.
Symptom management
function
Outputs the machine operation information.
*1 To use all the event notifying functions of the machine, install the external output option and MounterExtension on
the machine side.
*2 To use the mis-placement preventive function, install the external output option and GCI on the machine side and
enables the mis-placement preventive function in the machine setup. Install the barcode reader in the machine.
*3 To use the Off-line Setup function, make settings of the External Output option (*2) and enable the Off-line Setup
function with the machine.
*4 To use the traceability function, install the external output option on the machine side and enable the traceability
function in the machine setup. (It is necessary to use the mis-placement preventive function as a prerequisite.) The
hardware of the code reader must be purchased on the machine side.
*5 To use the IFS-NX linkage function, IFS-NX is required. (IFS-NX has to be set to be used with the machine, and the
option installer for IFS-NX is required. Any option installer of the machine for the External Output Function (such as
the installers for the machine event notification function, mis-placement preventive function and traceability function)
is not required.)
*6 To use the component storage control function, ISM is required.
*7 The mis-placement preventive function of an external output option is used on the machine side and the reel is
loaded. (This is not applicable when IFS-NX is used.)
*8 When the system extracts a component normally via the ISM Connection, it does not create any BOM information
because the component list is used for component extraction information if components are set to be extracted in the
normal way via the ISM Connection.
*9 When the system extracts a component in case of emergency via the ISM Connection, it sends a component deliv-
ery (extraction) order to the ISM Connection.
JaNets Product Specifications
2. JaNets External Output Function Overview
2-3
Devices and options required for each function
The devices and options (OP) of the external output function of JaNets are shown below.
There are 3 kinds of installer of external output options on the machine side.
Install one of them.
Table 1.3.1 The devices and OP of the external output function
Function to be used
JaNets
Machine *7
ISM
IFS-
NX
LM
EM
External
output OP
External output OP
Bar-
code
reader
GCI MEX
IFS
-NXO
P 2D,
etc.
OP1
*1
OP2
*2
OP3
*3
How to Use Each Function
- - - - - - - - - -
Line configuration output function
- - - - - - - - - -
Machine monitoring function *4
*5
- - - - - - - - -
The machine event notifying function *6
- - - - - - - -
The mis-placement preventive function *7
- - - - - -
Off-line Setup function *8
- - - - - - -
*9
-
Traceability function *7
- - - - - -
IFS-NX linkage function *10
-
- - - - - -
Parts stock
management
function
BOM information
output
-
- - - - - - - -
-
Residual number
updating and au-
tomatic delivery to
ISM *11
-
-
-
-
-
Machine operation function
- - - - - - - - - -
Symptom management function
-
- - - - - - - - -
How to Use Each Function *5
*5
- - - - - - - - -
(: Required / : Required in some cases / : Not required)
*1 The mis-placement preventive function of an external output option is used on the machine side and the reel is
loaded. (This is not applicable when IFS-NX is used.)
*2 OP installer to turn on External output function + Machine event notifying function + Mis-placement preventive func-
tion + Off-line Setup function
*3 OP installer to turn on External output function + Machine event notifying function + Mis-placement preventive func-
tion + Traceability function + Off-line Setup function
*4 The OP1 installer or the corresponding INFS-NX option is required to output production tact information.
* LM is an option of Line Manager.
* EM is an option of Equipment Manager.
* MEX is used as a MounterExtension installer.
*5 The Equipment Manger option is required only to output information on a printer or an inspection machine.
*6 To output the following information, you do not have to install the MounterExtension. However, you have to use the
Program Downloader to download/upload a production program.
- Production program downloading start information
- Production program downloading end information
- Production program uploading start information
- Production program uploading end information
Note that you have to use the IFS-NX linkage function to output the following information:
- Component shortage warning information
Machine production preparation start information is output also even though the Program Downloader is not used.
*7 The mis-placement preventive function and traceability function of the external output function cannot be used to-
gether with the mis-placement preventive function and traceability function of IFS-NX.
*8 The Off-line Setup function requires OP2 or higher.
*9 When the system is equipped with ISM, you can control the number of remaining components.
*10 To use the IFS-NX linkage function, IFS-NX is required. Any of OP1, OP2 and OP3 is not required.
*11 When ISM is used, the function “Residual number updating and automatic delivery to ISM” is enabled.
JaNets Product Specifications
2. JaNets External Output Function Overview
2-4
Installing the JaNets External Output Function on a Mounter.
See Section 8.3 “Procedure for Installing onto a Mounter” of Chapter 8 “Appendix” for how to install
the External Output Function on a mounter.
System Configuration
Supported machine models
The machine models that support the JaNets External output function are shown below.
Table 1.4.1 Supported machine models
Item Specifications Supported machine models
Maximum number of machines that can
be connected to one production line
10
RS-1/RS-1R
RX-7/RX-7R/RX-8
RX-6 (RX-6B *1) /RX-6R
KE-3010A/3020VA/3020VRA
KE-3010/3020V/3020VR
KE-3020/3020R
KE-2070/2080/2080R
KE-2050R/2055R/2060R
KE-2050/2060
FX-3/FX-3R/FX-3RA
KD-2077
JM-10/20/100
RP-1 *2
RP-2 *2 *3
RV-1/2/2-3D *2
Any combination of machine.
Maximum number of lines that can be
connected
15 line
Maximum number of machines that can
be connected
15
*1 An RX-6B shall be supported as an RX-6.
*2 The Equipment Manager license is required so that the system can be linked with a printer or an
inspection machine.
*3 When you use an RP-2, specify “GenericPrinter” as a machine model to create machine information
with the Shopfloor Setup. Note that the supported functions are the same as those of an RP-1.
However, the “Start interlock” of the machine operation function cannot be used.