JANETS_SPE_EN.pdf - 第27页
JaNets Prod uct S pecific ations 2. JaNets Exter nal Output Fu nction Overview 2-7 Information on end of producti on of the planned number of PWBs with the machine ProductionFinished Outputs information on a machine that…

JaNets Product Specifications
2. JaNets External Output Function Overview
2-6
Machine monitoring function
Information that can be output with the machine monitoring functions is described below.
Table 1.4.6 List of output information (with the machine monitoring function)
Information name
Command character
string
Description
Machine status
information
MachineStatus
Outputs machine status information (such as the status of the signal
lights and machine status transition: production, stop and waiting).
Total production
management in-
formation
TotalProduction
Outputs management information on production performed with a
machine.
Production tact
information
ProductionTactTime
Outputs the machine production tact (machine tact/line tact/champion
tact).
Information that can be output with each machine model is described below.
Table 1.4.7 List 1 of information that can be output with each machine model
(with the machine monitoring function)
Information name
RS-1
Series
RX-6
Series
RX-7/8
Series
KE-
3000
Series
FX-3
Series
KE-
2050/60
Series
KE-
2070/80
Series
KD-
2077
Machine status information ○ ○ ○ ○ ○ ○ ○ ○
Total production management information
○ ○ ○ ○ ○ ○ ○ ○
Production tact information ○ ○ - ○ - - - -
Table 1.4.8 List 2 of information that can be output with each machine model
(with the machine monitoring function)
Information name JM-10
JM-20
/JM-100
RV
Series
RP-1
Machine status information
○
○
○
○
Total production management information
○
○
○
○
Production tact information
-
○
-
-
Machine event notifying information
Information that can be output with the machine event notifying function is described below.
Table 1.4.9 List of output information (with the machine event notifying function)
Information name
Command character string
Description
Machine startup information MachinePowerOn Outputs information on a machine that started up.
Machine shutdown information MachinePowerOff Outputs information on a machine that was shut down.
Start button pressing information
MachineStartSelected
Outputs information on a machine that was put in the production
state.
Board ID load information *3 *7 ReadPwbId Outputs information on a board ID loaded with a machine.
Machine production start infor-
mation
*4 *7
ProductionStart
Outputs information on production that started placing a component
on a board.
Machine production end infor-
mation *2 *5 *7
ProductionComplete
Outputs information on production that finished placing a compo-
nent(s) on a board.
Machine production pause in-
formation *7
ProductionPause Outputs information on production stopped temporarily.
Machine production abort infor-
mation *2 *5 *7
ProductionAbort Outputs information on aborted production.
Component consumption infor-
mation *1
ComponentConsumption
Outputs information on a component(s) used not for production and
that on a component(s) only picked up and not placed on a board
during production of a single PWB.
* Information on a component(s) used for placement is output as
the Machine production end information/abort information.
Mispick information *1 Mispick Output information on a component picked up by mistake.
Component shortage information
*1
OutOfCompo Outputs information on components that run out.
Splicing point detection infor-
mation *1
SpliceDetected
Output information on a component at which a splicing point was
detected.
Machine production resume
information *7
ProductionResume
Outputs information on production that resumed from the pause
state.

JaNets Product Specifications
2. JaNets External Output Function Overview
2-7
Information on end of production
of the planned number of PWBs
with the machine
ProductionFinished
Outputs information on a machine that finished producing the
planned number of PWBs.
Information on cause of stop due
to an error
MachineStopCause Outputs machine error information or cause of the pause state.
Component shortage warning
information *6
OutOfCompoWarning
Outputs information on components whose quantity is less than the
warning value.
Production program download-
ing start information
ProgramDownloadStart
Outputs information on a machine that started downloading or the
name of a production program that started being downloaded.
Production program download-
ing end information
ProgramDownloadEnd
Outputs information on a machine that finished downloading or the
name of a production program that finished being downloaded.
Production program uploading
start information
ProgramUploadStart
Outputs information on a machine that started uploading or the
name of a production program that started being uploaded.
Production program uploading
end information
ProgramUploadEnd
Outputs information on a machine that finished uploading or the
name of a production program that finished being uploaded.
Board width adjustment start
information
AutoWidthConveyorStart
Outputs information on a machine that started adjusting the board
width or the operation type.
Board width adjustment end
information
AutoWidthConveyorEnd
Outputs information on a machine that finished adjusting the board
width or the operation result.
Production pause buzzer ON
information
ProductionStopBuzzerOn
Outputs information on a machine whose pause buzzer was set to
ON.
Production pause buzzer OFF
information
ProductionStopBuzzerOff
Outputs information on a machine whose pause buzzer was set to
OFF.
Simultaneous component
pick-up failure information
UnachievedParallelPick
Outputs information on a machine that failed to pick up components
simultaneously or where such a failure occurred.
Simultaneous component
pick-up failure cancel information
AchievedParallelPick
Outputs information on a machine whose simultaneous component
pick-up failure was cancelled.
Machine production preparation
start information
ProductionPreparationStart Outputs information on production performed by clamping a board.
CVS inspection result infor-
mation
CvsInspectionResults Outputs CVS inspection result information.
Machine heartbeat information MachineHeartbeat Outputs machine heartbeat.
Information that can be output depending on a machine model is described below.
Table 1.4.10 List 1 of information that can be output with each machine model
(with the machine event notifying function)
Information name
RS-1
Series
RX-6
Series
RX-7/8
Series
KE-
3000
Series
FX-3
Series
KE-
2050/60
Series
KE-
2070/80
Series
KD-
2077
Machine startup information
○ ○ ○ ○ ○ ○ ○
-
Machine shutdown information
○ ○ ○ ○ ○ ○ ○
-
Start button pressing information
○ ○ ○ ○ ○ ○ ○
-
Board ID load information *3 *7
○ ○ ○ ○ ○ ○ ○
-
Machine production start information *4 *7
○ ○ ○ ○ ○ ○ ○
-
Machine production end information *2 *5 *7
○ ○ ○ ○ ○ ○ ○
-
Machine production pause information *7
○ ○ ○ ○ ○ ○ ○
-
Machine production abort information *2 *5 *7
○ ○ ○ ○ ○ ○ ○
-
Component consumption information *1
○ ○ ○ ○ ○ ○ ○
-
Mispick information *1
○ ○ ○ ○ ○ ○ ○
-
Component shortage information *1
○ ○ ○ ○ ○ ○ ○
-
Splicing point detection information *1
○ ○ ○ ○ ○ ○ ○
-
Machine production resume information *7
○ ○ ○ ○ ○ ○ ○
-
Information on end of production of the planned number
of PWBs with the machine
○ ○ ○ ○ ○ ○ ○
-
Information on cause of stop due to an error
○ ○
-
○
- - - -
Component shortage warning information *6
○ ○
-
○
- - - -
Production program downloading start information
○ ○ ○ ○ ○ ○ ○ ○
Production program downloading end information
○ ○ ○ ○ ○ ○ ○ ○
Production program uploading start information
○ ○ ○ ○ ○ ○ ○ ○
Production program uploading end information
○ ○ ○ ○ ○ ○ ○ ○
Board width adjustment start information
○ ○
-
○
- - - -
Board width adjustment end information
○ ○
-
○
- - - -
Production pause buzzer ON information
○ ○
-
○
- - - -

JaNets Product Specifications
2. JaNets External Output Function Overview
2-8
Production pause buzzer OFF information
○ ○
-
○
- - - -
Simultaneous component pick-up failure information ○ ○ - ○ - - - -
Simultaneous component pick-up failure cancel
information
○ ○
-
○
- - - -
Machine production preparation start information
○ ○
-
○
- - - -
CVS inspection result information *8
○
-
○
- - - - -
Machine heartbeat information ○ ○ ○ ○ ○ ○ ○ -
Table 1.4.11 List 2 of information that can be output with each machine model
(with the machine event notifying function)
Information name JM-10 JM-20 JM-100
RV
Series
RP-1
Machine startup information -
○ ○ ○
-
Machine shutdown information - ○ ○ ○ -
Start button pressing information -
○ ○ ○
-
Board ID load information *3 *7 -
○ ○ ○
-
Machine production start information *4 *7 - ○ ○ ○ -
Machine production end information *2 *5 *7 -
○ ○ ○
-
Machine production pause information *7 -
○ ○
- -
Machine production abort information *2 *5 *7 - ○ ○ ○ -
Component consumption information *1 -
○ ○
- -
Mispick information *1 -
○ ○
- -
Component shortage information *1 - ○ ○ - -
Splicing point detection information *1 -
○ ○
- -
Machine production resume information *7 -
○ ○
- -
Information on end of production of the planned number of
PWBs with the machine
- ○ ○ - -
Information on cause of stop due to an error - -
○ ○
-
Component shortage warning information *6 - -
○
- -
Production program downloading start information
○
○
○
○
○
Production program downloading end information
○
○
○
○
○
Production program uploading start information
○
○
○
○
○
Production program uploading end information
○
○
○
○
○
Board width adjustment start information - -
○
- -
Board width adjustment end information - -
○
- -
Production pause buzzer ON information - - ○ ○ -
Production pause buzzer OFF information - -
○ ○
-
Simultaneous component pick-up failure information - -
○
- -
Simultaneous component pick-up failure cancel infor-
mation
- - ○ - -
Machine production preparation start information - -
○
- -
CVS inspection result information - - - - -
Machine heartbeat information
-
○
○
-
-
*1 When you use the erroneous mounting preventive function of IFS-NX or the External Output option, this in-
formation can be output.
*2 Information on the number of remaining components is added when you use the erroneous mounting preven-
tive function of IFS-NX or the External Output option.
*3 When you use the traceability function of IFS-NX or the External Output option, this information can be output.
*4 A board ID is added when you use the traceability function of IFS-NX or the External Output option.
*5 Traceability information is added when you use the traceability function of IFS-NX or the External Output op-
tion.
*6 When you use the erroneous mounting preventive function of the External Output option, this information can
be output.
*7 This information is output for each circuit when a board ID is set to be read for each circuit.
*8 The CVS inspection result information is not output by an RX-8.