JaNets Product Specifications
2. JaNets External Output Function Overview
2-8
Production pause buzzer OFF information
-
- - - -
Simultaneous component pick-up failure information - - - - -
Simultaneous component pick-up failure cancel
information
-
- - - -
Machine production preparation start information
-
- - - -
CVS inspection result information *8
-
- - - - -
Machine heartbeat information -
Table 1.4.11 List 2 of information that can be output with each machine model
(with the machine event notifying function)
Information name JM-10 JM-20 JM-100
RV
Series
RP-1
Machine startup information -
-
Machine shutdown information - -
Start button pressing information -
-
Board ID load information *3 *7 -
-
Machine production start information *4 *7 - -
Machine production end information *2 *5 *7 -
-
Machine production pause information *7 -
- -
Machine production abort information *2 *5 *7 - -
Component consumption information *1 -
- -
Mispick information *1 -
- -
Component shortage information *1 - - -
Splicing point detection information *1 -
- -
Machine production resume information *7 -
- -
Information on end of production of the planned number of
PWBs with the machine
- - -
Information on cause of stop due to an error - -
-
Component shortage warning information *6 - -
- -
Production program downloading start information
Production program downloading end information
Production program uploading start information
Production program uploading end information
Board width adjustment start information - -
- -
Board width adjustment end information - -
- -
Production pause buzzer ON information - - -
Production pause buzzer OFF information - -
-
Simultaneous component pick-up failure information - -
- -
Simultaneous component pick-up failure cancel infor-
mation
- - - -
Machine production preparation start information - -
- -
CVS inspection result information - - - - -
Machine heartbeat information
-
-
-
*1 When you use the erroneous mounting preventive function of IFS-NX or the External Output option, this in-
formation can be output.
*2 Information on the number of remaining components is added when you use the erroneous mounting preven-
tive function of IFS-NX or the External Output option.
*3 When you use the traceability function of IFS-NX or the External Output option, this information can be output.
*4 A board ID is added when you use the traceability function of IFS-NX or the External Output option.
*5 Traceability information is added when you use the traceability function of IFS-NX or the External Output op-
tion.
*6 When you use the erroneous mounting preventive function of the External Output option, this information can
be output.
*7 This information is output for each circuit when a board ID is set to be read for each circuit.
*8 The CVS inspection result information is not output by an RX-8.
JaNets Product Specifications
2. JaNets External Output Function Overview
2-9
Erroneous mounting preventive function
Information that can be output with the erroneous mounting preventive functions is described below.
Table 1.4.12 List of output information (with the erroneous mounting preventive function)
Information name
Command
character string
Description
Machine reel information *1
OneReel
Outputs information on loaded/unloaded/spliced components.
Information that can be output with each machine model is described below.
Table 1.4.13 List 1 of information that can be output with each machine model
(with the erroneous mounting preventive function)
Information name
RS-1
Series
RX-6
Series
RX-7/8
Series
KE-
3000
Series
FX-3
Series
KE-
2050/60
Series
KE-
2070/80
Series
KD-
2077
Machine reel information *1
-
Table 1.4.14 List 2 of information that can be output with each machine model
(with the erroneous mounting preventive function)
Information name JM-10
JM-20
/JM-100
RV
Series
RP-1
Machine reel information *1 - - -
*1 When you use the erroneous mounting preventive function of IFS-NX or the External Output option,
this information can be output.
Automatic delivery function
Information that can be output with the automatic delivery functions is described below.
Table 1.4.15 List of output information (with the automatic delivery function)
Information name
Command character
string
Description
Reel delivery information ReelDelivery
Outputs information on a component whose delivery is re-
quested to the storage system.
Information that can be output with each machine model is described below.
Table 1.4.16 List 1 of information that can be output with each machine model
(with the automatic delivery function)
Information name
RS-1
Series
RX-6
Series
RX-7/8
Series
KE-
3000
Series
FX-3
Series
KE-
2050/60
Series
KE-
2070/80
Series
KD-
2077
Reel delivery information
-
Table 1.4.17 List 2 of information that can be output with each machine model
(with the automatic delivery function)
Information name JM-10
JM-20
/JM-100
RV
Series
RP-1
Reel delivery information
-
-
-
JaNets Product Specifications
2. JaNets External Output Function Overview
2-10
Machine operation function
Information that can be output with the machine operation functions is described below.
Table 1.4.18 List of output information (with the machine operation function)
Information name
Command character string
Description
Operation result information OperationResult
Outputs the result of a requested operation (Production
pause/Production abort/ cycle stop).
Start interlock request RequestStartInterlock Outputs the production start request from a machine.
Program Downloader online
production status information
ProgramDownloaderOnlineStatus
Outputs the production status or production information of
the monitored production line.
Production program open
result information
ResultProductionProgramOpen Outputs the result of the production program open request.
Production registration cancel
result information
ResultCancelProductionProgram
Outputs the result of the production registration cancel
request.
Production line download
result information
ResultLineProductionProgramDownload Outputs the result of a production line download request.
Information that can be output with each machine model is described below.
Table 1.4.19 List 1 of information that can be output with each machine model
(with the machine operation function)
Information name
RS-1
Series
RX-6
Series
RX-7/8
Series
KE-
3000
Series
FX-3
Series
KE-
2050/60
Series
KE-
2070/80
Series
KD-
2077
Operation result information
(Production pause)
Operation result information
(Production abort)
Operation result information (Cycle stop) - - - -
Start interlock request
- - - -
Table 1.4.20 List 2 of information that can be output with each machine model
(with the machine operation function)
Information name JM-10
JM-20
/JM-100
RV
Series
RP-1
Operation result information (Production pause) - -
Operation result information (Production abort)
Operation result information (Cycle stop) -
Start interlock request -
* Since the Program Downloader online production status information, the Production program open re-
sult information, Production registration cancel result information and Production line download result
information are on each monitored production line individually, they can be output regardless of ma-
chine models.
Symptom management function
Information that can be output with the symptom management functions is described below.
Table 1.4.21 List of output information (with the Symptom management function)
Information name
Command character string
Description
Device operation
information
MachineManagement
Outputs information on operation of a device re-
quired to forecast maintenance to be performed.
Production nozzle
management information
ProductionNozzleManagement
Outputs information on operation of a nozzle of a
machine that is producing a PWB.
Total nozzle management
information
TotalNozzleManagement Outputs accumulated nozzle operation information.