M6ex_ServiceManual_e.pdf - 第69页

4 Electrical Section 4-3 ■ Details tab Action: ① Select Tool>StartScan to display each sensor status. ② Select Tool>EndScan to end. ■ FIO tab ■ Feeder tab “1” indicates that the feeder has been set. “0” indicates t…

100%1 / 100
4 Electrical Section
4-2
Signal I/O
Signal I/O is the abbreviation of signal input/output. The signal input refers to the input signal via the
sensors. The signal output refers to the command transmitted to the actuators.
Signal Output (Control) window serves as controls to move actuators for checking their movements. In
response to their movements, Signal Input (Monitor) window shows On/Off of motors and actuators.
Note: The Signal Input and Signal Out put windows are opened at the same time. You can move actuators using
the Signal Output window while simultaneously checking the signal input status in the Signal Input
window.
Signal Input Monitor
You can check On/Off of the sensors real-time. “1” indicates on, “0” off. When a sensor of a switch, motor,
and actuator responds, the change of the sensor status is shown real-time. Wire disconnection or sensor
failure can also be detected.
Menu: Manual>Signal I/O>Signal Input (Monitor)
These menus allow you to check each sensor status real-time. You can specify the sampling cycle for the
status check.
List tab
Changing the Sampling Cycle
Action:
Select Option>SampingCycle.
Enter sampling cycle (ms) larger than the minimum of 300, and click <OK> button.
Select Tool>StartScan to start checking.
Select Tool>EndScan to end.
Note: Use the minimum sampling cycle (300) normally.
Note: The combination of an address and bit number (0-7) represents a signal. The name of each signal is shown
in the Details tab.
4 Electrical Section
4-3
Details tab
Action:
Select Tool>StartScan to display each sensor status.
Select Tool>EndScan to end.
FIO tab
Feeder tab
“1” indicates that the feeder has been set.
“0” indicates that the feeder has not been set yet.
4 Electrical Section
4-4
Motor tab
Motor Sensor tab
Window:
ALM: Alarm
MEL: Minus End Limited
PEL: Plus End Limited
MARK: Mark
INP: In Position
MSLD: Minus Slow Down
PSLD: Plus Slow Down
EZ: 0 Phase
ORG: Origin