5OM-1732-003Y_F8_资料.pdf - 第134页

5OM-1732 4-1-48 1206-001 搬送 IO 线路板 U14 部 PCB Stopper 1 Lower Limit Detection PCB Stopper 1 Upper Limit Detection PCB Stopper 2 Lower Limit Detection PCB Stopper 2 Upper Limit Detection PCB Stopper 3 Lower Limit Detection…

100%1 / 142
5OM-1732
4-1-471206-001
搬送 IO 线路板 008
PCB Stopper 1 Lower Limit Detection
PCB Stopper 1 Upper Limit Detection
PCB Stopper 2 Lower Limit Detection
PCB Stopper 2 Upper Limit Detection
PCB Stopper 3 Lower Limit Detection
PCB Stopper 3 Upper Limit Detection
Movable Chute Back up Pin Sensor 1
S1 Fixed Z-Clamp Lower Limit Detection
S2 Fixed Z-Clamp Lower Limit Detection
Feeder (Rear)
U14 (Transfer IO)
Note
Note 1. The drain cable should be connected
to the connector case.
FG (Connector Case)
FG (Connector Case)
FG (Connector Case)
Note 1 Note 1 Note 1
PCB Stop Sensor Input Section 5 Remote
PCB Stop Sensor Input Section 4 Remote
PCB Stop Sensor Input Section 3 Remote
PCB Stop Sensor Input Section 1 Remote
PCB Stop Sensor Input Section 1 Remote
PCB Stop Sensor Input Section 6 Remote
S1 Z-Clamp Cylinder Valve 1
(A : Down)
S1 Z-Clamp Cylinder Valve 2
(B : Up)
S2 Z-Clamp Cylinder Valve 2
(B : Up)
PCB Stopper 1 UP/DOWN Valve
PCB Stopper 2 UP/DOWN Valve
PCB Stopper 3 UP/DOWN Valve
PCB Stop Sensor Placement Section 1 Remote
PCB Stop Sensor Placement Section 2 Remote
PCB Stop Sensor Placement Section 3 Remote
PCB Stop Sensor Placement Section 4 Remote
PCB Stop Sensor Input Section 5 Remote
PCB Stop Sensor Input Section 6 Remote
Backup Pin Conveyor Emergency Stop (UC18)
S2 Z-Clamp Cylinder Valve 1
(A : Down)
5OM-1732
4-1-48
1206-001
搬送 IO 线路板 U14
PCB Stopper 1 Lower Limit Detection
PCB Stopper 1 Upper Limit Detection
PCB Stopper 2 Lower Limit Detection
PCB Stopper 2 Upper Limit Detection
PCB Stopper 3 Lower Limit Detection
PCB Stopper 3 Upper Limit Detection
Movable Chute Back up Pin Sensor 1
S1 Fixed Z-Clamp Lower Limit Detection
S2 Fixed Z-Clamp Lower Limit Detection
Note
Note 1. The drain cable should be connected
to the connector case.
U08 (Transfer IO)
FG (Connector Case)
FG (Connector Case)
FG (Connector Case)
Note 1
PCB Stop Sensor Input Section 5 Remote
PCB Stop Sensor Input Section 4 Remote
PCB Stop Sensor Input Section 3 Remote
PCB Stop Sensor Input Section 1 Remote
PCB Stop Sensor Input Section 1 Remote
PCB Stop Sensor Input Section 6 Remote
S1 Z-Clamp Cylinder Valve 1
(A : Down)
S1 Z-Clamp Cylinder Valve 2
(B : Up)
S2 Z-Clamp Cylinder Valve 2
(B : Up)
PCB Stopper 1 UP/DOWN Valve
PCB Stopper 2 UP/DOWN Valve
PCB Stopper 3 UP/DOWN Valve
PCB Stop Sensor Placement Section 1 Remote
PCB Stop Sensor Placement Section 2 Remote
PCB Stop Sensor Placement Section 3 Remote
PCB Stop Sensor Placement Section 4 Remote
PCB Stop Sensor Input Section 5 Remote
PCB Stop Sensor Input Section 6 Remote
Backup Pin Conveyor Emergency Stop (UC18)
S2 Z-Clamp Cylinder Valve 1
(A : Down)
5OM-1732
4-1-49
机械电缆连接图
1208-002
On the Main Machine Side
DC48V Power
Earthing
Earthing
(Rear)
P.C.B Height
Head IL
Reserve
Head ILB
P.C.B Height
Head IL
Reserve
On the Main Machine Side
DC48V Power
Earthing
Earthing
(Front)
Head ILB
24A6
24A6
Case