00198612-02_VD_SIPLACE_Pro_16.1_R19-1_DE_EN.pdf - 第13页

SIPLACE Pro 16.1 (R19-1) / Version Description 05/2019 Edition 13 – Carrier X (XTH) (X2, X 3, X4 on location 2 and 4 only) – Carrier SX (SX1/S X2 with Twin Head and CPP head only) – MTC2 (X2, X3, X 4 on location 2 and 4,…

100%1 / 82
SIPLACE Pro 16.1 (R19-1) / Version Description 05/2019 Edition
12
NOTICE
The following station software versions are not supported by SIPLACE Pro anymore:
– 506
– 601, 602, 603, 604
– 701, 702, 703, 704
If a station with one of the removed versions exists in SIPLACE Pro, the version will be
set to the following supported version of the corresponding platform:
– 505 Full
– 605
– 707
3.2 Supported DEK Printer Software Versions and Printer Types
DEK Printer Version
Printer Types
DEK Printer Software Version V09
(Printer Programming 1.0)
DEK Printers running V09 software
*)
Table 3-2: Supported DEK printer software versions and printer types
*)
The version number listed above is accurate at the time of compiling this document.
Please note that it is subject to change without prior notice. For further details please contact your
sales representative.
3.3 Supported Feeder Types
The following feeders are supported by SIPLACE Pro:
Feeder Modules from ASM Assembly Systems
– 4 mm – 104 mm X-feeder
– 8 mm - 88 mm E (E-series only)
– 2x8 mm X-feeder
– 16 mm XN-feeder
– Surftape AX (8 mm, 12 mm, 16 mm)
– LED feeder TE
LED feeder HS
– SIPLACE JTF-S (X-series S and SX1/SX2 V2 only)
– SIPLACE JTF-M (X-series S, X4i S micron and SX1/SX2 V2 only)
– SIPLACE JTF-ML 14X and JTF-ML 18X (TX-series only)
– SIPLACE JTF-ML2 7/7 and JTF-ML2 9/9 (TX-series only)
– JTF-MW E (E-series only)
– SIPLACE BulkFeeder X
– Arbitrary Carrier X
– Conveyor Carrier X
SIPLACE Pro 16.1 (R19-1) / Version Description 05/2019 Edition
13
– Carrier X (XTH) (X2, X3, X4 on location 2 and 4 only)
– Carrier SX (SX1/SX2 with Twin Head and CPP head only)
– MTC2 (X2, X3, X4 on location 2 and 4, X2 S, X3 S, X4 S on location 2)
– WPC5 / WPC6 (SX1/SX2, X-series S on location 2)
– SIPLACE Wafer Systems (CA-series only)
– Stick feeder with X-adapter
Processing Feeders from ASM Assembly Systems
– MeasuringFeeder X
– SIPLACE Glue Feeder
– Reject conveyor with X-adapter
– Linear Dipping Module X
– Linear Dipping Unit 2 X
– Linear Dipping Unit 2 E (E-series only)
– Label feeder with X-adapter
– Splice sensor X-feeder
Modules from 3
rd
party suppliers
– FFI feeders:
Data IO RoadRunners
– IPTE Multi Stick Feeder:
IPTE MSF 60 AX
IPTE MSF XL80 AX
– SEMO CRF80 tape feeder
SIPLACE Pro 16.1 (R19-1) / Version Description 05/2019 Edition
14
4 Features of SIPLACE Pro 16.1
4.1 Using Individual Pickup Error Thresholds for Components
The station software issues warning and error messages when pickup errors occur (including vision
errors). These warning and error messages are triggered by threshold values, which, by default,
are identical for all tracks. However, it is now possible to configure these threshold values
individually for components in SIPLACE Pro, overruling the default values from the station
software.
This feature can be activated using the Use individual values checkbox in the Component Editor.
4.2 Hardware Changes
Station Type SIPLACE TX2i W as New Standard Machine
SIPLACE Pro supports the TX2i W as standard machine. The following conveyor wideness settings
are supported:
– Position 231
– Position 268 SMEMA
– Position 281 SMEMA
– Position 301
CPP 20 20xx Nozzle Changer Magazine Type as New Default Magazine
All default nozzle changer magazines CPP 12 20xx are replaced by the CPP 20 20xx. If a new
nozzle changer of this type is created in SIPLACE Pro, the magazine with 20 pockets is set up by
default. This affects the stations X2, X3, X4, X4i, SX4, CA4, CA4V2, X2 S, X3 S, X4 S, X4i S, SX,
SX V2, TX and TX V2 regardless of the used station software version.
Already existing setups are not affected. If the magazine is fixed, the SIPLACE Pro Optimizer does
not change the magazine from 12 pockets to 20 either.
Customers who want to use 12 pockets must reset these pocket types on their own.
Restrictions
– The default setting for magazines is independent from the used station software. Therefore,
even SIRIO stations running with software versions that do not support the new magazine type
are affected by this change.
– SIPLACE Pro does not check if a magazine with 20 pockets is set on a station that is run with a
station software version < 709. In this case, a configuration error occurs on the station.